Journal of Conservative Dentistry
Home About us Editorial Board Instructions Submission Subscribe Advertise Contact e-Alerts Login 
Users Online: 1112
Print this page  Email this page Bookmark this page Small font sizeDefault font sizeIncrease font size
 

 
Table of Contents   
ORIGINAL ARTICLE  
Year : 2021  |  Volume : 24  |  Issue : 6  |  Page : 553-557
Polyether ether ketone – As an alternative biomaterial for Metal Richmond crown-3-dimensional finite element analysis


1 Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India
2 Department of Pedodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India

Click here for correspondence address and email

Date of Submission21-Dec-2020
Date of Decision19-Nov-2021
Date of Acceptance25-Nov-2021
Date of Web Publication01-Apr-2022
 

   Abstract 


Aim: This study was aimed to analyze the stress generation and distribution for “polyether ether ketone (PEEK)” and metal cobalt-chromium (Co-Cr) at different locations of the tooth using finite element analysis (FEA), when they are casted-off as “Richmond crowns.”
Materials and Methods: The model of the tooth was designed using “computer-aided design/computer-aided manufacturing” followed by generating the “Mesh” of the tooth to analyze the stress caused by applying vertical and oblique loads of 100N and 40N, respectively, in cubical nodes for both PEEK and metal endodontic post-based Richmond crown. The “3-dimensional von Mises criteria” was used to compare stresses of both elements using FEA. The material properties for each component were designated by respective modulus of elasticity and Poisson's ratio. The statistical test of the stress generation in various locations of PEEK and Metal (Co-Cr) Richmond crown was done by independent t-test.
Results: From the FEA analysis of Richmond crown, it is evident that maximum stress was generated by “Metal” of about 66.418 MPa when compared to “PEEK” (15.826 MPa). “PEEK Richmond crown” produced minimal stress on the tooth and the other surrounding regions than “Metal Richmond crown” with a statistically significant difference (P < 0.05).
Conclusion: The results proved that the “Metal Richmond crown” postsystem had a tendency to produce more stress on the tooth and the other surrounding regions than the PEEK. The FEA proved the pros of using “PEEK post Richmond crown,” which is a big boon for the modern era dentistry.

Keywords: Endodontically treated teeth, finite element analysis, polyether ether ketone, Richmond crown, stress

How to cite this article:
Aparna J, Maiti S, Jessy P. Polyether ether ketone – As an alternative biomaterial for Metal Richmond crown-3-dimensional finite element analysis. J Conserv Dent 2021;24:553-7

How to cite this URL:
Aparna J, Maiti S, Jessy P. Polyether ether ketone – As an alternative biomaterial for Metal Richmond crown-3-dimensional finite element analysis. J Conserv Dent [serial online] 2021 [cited 2023 Sep 22];24:553-7. Available from: https://www.jcd.org.in/text.asp?2021/24/6/553/342487



   Introduction Top


The main objective of restorative dentistry is to restore the characteristic and esthetic features of the teeth that have severely damaged or compromised their tooth structure due to trauma, caries, and fracture.[1] Wherever the existing weakened or impaired crown structure is inadequate to retain a full-coverage crown, then the “post and core” system is needed to improve retention and resistance.[2] However, “post and core” protocols can lead to problems such as dislocation of assembly, fracture of post or root, deprivation of the restorative seal, periodontal ligament, and bone injury.[3]

The Richmond crown is a good alternative treatment to restore the injured teeth. The main purpose of a “post” is to retain a core in a tooth that has lost its crown structure extensively.[4] The main application of Richmond crown is that it can be used in the badly broken single tooth where the remaining height of the crown is very low. The advantages of using this design include custom fitting to the root structure, low or no stress generation at the cervical margin, and high strength when the “post and core” are two separate entities. The “post” reflection under functional forces produces stress on the postcore interface which leads to the separation due to the “post” deformation. “Core” breakdown leads to caries or crown dislodge. Therefore, uniting the post, core, and crown as a single component is good for retaining long-term stability.[5] This system is not popularly used because the high-stress generation surrounding the post leads to failure which can be eliminated by changing the material.[1] Polyether ether ketone (PEEK) and semi-crystalline thermoplastic material with good mechanical and chemical resistance properties with a low-elasticity modulus (8 − 10 GPa) and is of low plaque affinity can be a material of choice for endodontic post and Richmond crown system.[6]

The finite element analysis (FEA) is an approved method for inducing biophysical phenomena in computerized teeth models and their periodontium in the finite-element method is considered an extremely useful tool for simulating the mechanical effects of chewing forces acting on the periodontal ligament and the hard-dental tissue.[7] Deformations and stresses can be assessed at any point within the model and regions with higher stresses can be analyzed. Each dimension in the elastic modulus and the Poisson's ratio are defined for the model materials. A system of simultaneous equations is developed and solved throughout a structure to yield predictable stress distribution.[8] Even though many previous literatures are present on “FEA,” this will be the first study to report on “Richmond crown.” The main aim of this study was to compare the stress generation and distribution between PEEK and metal cobalt-chromium (Co-Cr) as a Richmond crown using the FEA.


   Materials and Methods Top


The study protocol was approved by the Institutional Review Board with the ethical committee number IHEC/SDC/UG-1842/21/118. This study was carried out in a tertiary care Dental College and Hospital in Tamilnadu, India.

Computer-aided design/computer-aided manufacturing modeling

This study was done by initially designing an axisymmetric model representing the various parts of the structure, i.e., gutta-percha, post, core, root, and crown of the posterior tooth (mandibular second premolar) with a proper geometry of each component using computer-aided design/computer-aided manufacturing modeling process [Figure 1]a and [Figure 1]b. The dimensions of various parts in the finite element model were taken as given by various researchers and obtained from standard dental literature.[1],[7],[9] Three dimensional FEA model was simulated, and elastic moduli and Poisson's ratio of all the materials were fed to the software and the “finite element model geometry” was obtained on the computer screen by the provision of various entities such as grids, lines, and patches.
Figure 1: Model preparation and load application. (a) Axisymmetric model representing the various parts in cross section. (b) The final element model geometry obtained on the computer screen by the provision of various entities such as grids, lines, and patches. (c) The mesh of the tooth model was created by segmenting the entire tooth structure into small cubical forms to analyze the stress caused in each cube. (d) A static load of a 100N and 40N were simultaneously applied on the second premolar tooth in a vertical and oblique direction (30° angulations), respectively for both the materials (i.e., polyether ether ketone and Metal)

Click here to view


Mesh generation

The element form was defined as the solid brick, the four-node element, and the material properties were the options for the meshing purpose. The material properties specified were the modulus of elasticity and Poisson's ratio [Table 1]. Using the material properties for each material and the element specified, the model was meshed with the help of the meshing tool. Meshing generated 159,627 elements interconnected by 36,108 nodes. Then, the mesh of the tooth model was created by segmenting the entire tooth structure into small cubical forms to analyze the stress caused in each cube, and then we finally summarized the stress caused on the cubes connecting different elements of the teeth. These corner points of cubes on which the stress is measured are called nodes which were done using the MeshLab software [Figure 1]c.
Table 1: Modulus of elasticity and Poisson's ratio for each component of the tooth

Click here to view


Application of loads

A static load of 100N and 40N were simultaneously applied on the tooth in a vertical and oblique direction (30° angulations), respectively, for both the materials (i.e., PEEK and Metal). The Richmond crown was previously designed by varying the modulus of elasticity and Poisson's ratio for each material and component [Figure 1]d.

Finite element analysis

The data files created in the preprocessor were used to provide solutions and displacement. FEA was performed for both PEEK and Richmond crown. The results and data obtained from the study were analyzed using the 3-dimensional (3D) von Mises criteria.[10] The output data for each material and type of post was obtained as the color-coded diagrams where similar colors depict the same range of stresses generated and warmer colors represent higher stresses (i.e., the blue color which indicates the least stress to red color which indicates the maximum stress) caused on that particular element using finite element modeling and postprocessing software. This was done to determine the employment of durable and comfortable material in patients. The stress pattern and maximum value of the generated von Mises stress were used to give the output of the study as it indicates the site where yielding of ductile material is likely to occur. The statistical test to find association of stress generation in various locations for PEEK and Metal (Co-Cr) Richmond crown was done by “independent t-test” using the IBM-SPSS (Statistical Package for the Social Sciences) Version 24.0 (IBM Corporation, Chicago, USA).


   Results Top


Polyether ether ketone

“Deformation” is the displacement caused due to increased stress as a result of increased load in which the PEEK Richmond crown exposed 0.0521 mm of total deformity. From the FEA analysis, it is evident that PEEK Richmond crown showed the maximum of 15.826 Mpa stress where mean stress 2.81 Mpa around the post, 0.57 Mpa around the trabecular bone, and 3.526 Mpa stress generation around the cortical bone [Table 2], [Figure 2]a and [Figure 2]b.
Table 2: Comparative evaluation of stress generation around the post between polyether ether ketone and Metal Richmond crown in which P value derived from independent t-test

Click here to view
Figure 2: Finite element analysis. (a) Total deformation caused in polyether ether ketone Richmond crown. (b) Maximum stress caused in PEEK Richmond crown. (c) Total deformation caused in the Metal Richmond crown. (d) Maximum stress caused in Metal Richmond crown

Click here to view


Metal cobalt-chromium

Deformation in Metal (Co-Cr) Richmond crown exposed 0.0569 mm of total deformity. From the FEA analysis, it is evident that maximum stress is caused around the Metal Richmond crown which is 66.418 Mpa, where mean stress is 16.113 Mpa around the post, 1.004 Mpa around the trabecular bone, and 5.887 Mpa stress generation around the cortical bone [Table 2], [Figure 2]c and [Figure 2]d.

On statistical analysis (independent t-test), the difference of stress generation between Metal and PEEK was statistically significant (P < 0.05).


   Discussion Top


A root fracture is an unwanted incident for a postcore restored endodontically treated tooth. When a metal “post and core” is used as an intraradicular “post and core,” vertical root fractures often occur, and leading to tooth extraction. A prefabricated fiberglass post and resin core is commonly used as a “post and core” device to avoid several vertical root fractures. Because fiberglass has a lower elastic modulus than metal, fiberglass postsystems of similar strength induce desirable stress distributions within the root and typically exhibit a repairable horizontal fracture mode when root fractures occur.[3] Although fiberglass has a lower elastic modulus than metal, its elastic modulus is higher than dentin.

The Richmond crown is a single-unit “post and core.” This design has advantages such as being fitted to the root configuration, having little or no stress on the cervical margin. “Post and core” restorations are multicomponent complex systems wherein the stress distribution within the structure is multiaxial, nonuniform, and depends on the magnitude and direction of the applied external loads.[11] A well-known computational tool for measuring stress distribution within such a complex structure is the FEM, which enables researchers to determine the effect of model parameter variance once the basic model has been properly designed.[9] Hence the present study was conducted using 3D FEA to test the biomechanical behavior and long-term protection of the PEEK “postcore” system as a single unit “Richmond crown” in the radicular tooth structure and also the stress distribution analysis was carried out using the von Mises criterion as a quantitative association of maximum stress.[12]

It was found that these materials, when subject to specific loading conditions, have an effect on the pattern of stress distribution within the restore-tooth complex. When a restoration-tooth complex is subjected to loading, a combination of shear and maximum principal stress develops within the system (known as the complex stress state).[13] Since the von Mises criteria method depends on the entire stress field, it has been commonly used as an indicator for the possibility of damage occurrence.[10]

Furthermore, previous literature showed that stress on the fiber post is distributed more evenly in the posttip area, whereas in the metal posthigh stress is concentrated around the teeth.[14],[15],[16] Another FEA study proved the stress accumulation within the cast “post and core” system is more than fiber post.[17] According to the previous literature, “fiber post” showed more homogenous stress distribution and better biomechanical performance than “metallic post” because the stiffness of fiber post is similar to dentin.[18],[19] This proves that both metal and fiber posts shave high-stress distribution.

In the present study, “PEEK” had given the best result in regard to stress distribution which was least when compared to a “metal post.” The experimental results of stress analysis showed a high correlation with FEA predictions, which is in accordance with the previous study conducted by Değer et al., which concluded that “glass and carbon posts” display high-stress distribution, tensile strength, and have Young's modulus when compared to dentin.[20] Due to the reason that the vertical static loads with “fiber posts” restored teeth substantially stronger than those with “metal posts.” This suggested that metallic posts could cause root fractures in pulpless teeth under the influence of vertical static loading but fiber posts did not trigger or accelerate vertical root fracture. This study has shown to be an effective outcome at testing the “PEEK Richmond crown” showing the benefit of using it over metal one.

A study conducted by Pegoretti et al. observed the influence of different postdesigns and composition on stress distribution on maxillary central incisor: finite analysis of the elements showed that the limitations related to the assumption that stress distributions in all vertical sections are identically parallel to the selected two-dimensional model (plane strain assumption), hence we used 3D analysis in this present study which is more accurate to obtain standardized results when compared to two-dimensional models. Many authors also considered that 3D models are definitely more accurate in describing the actual stress conditions.[21]

Therefore, it is evident that “PEEK Richmond crown” can resist tooth fracture due to high modulus of elasticity and it also increases the lifespan of the prosthesis which will act as a viable option for upcoming digital dentistry, as a new horizon in dental technology and material science. Possible limitations of this study include that “PEEK Richmond crown” is very costly, time-consuming, and they are mostly applicable for highly demanding applications. To sum up, further extensive clinical research is required to know about the efficacy and successful outcome of this treatment.

Clinical implications

Endodontically treated tooth with “Metal Richmond crown” can cause tooth fracture due to high-stress generation, whereas “PEEK Richmond crown” aids in distributing less stress around the tooth to prevent fracture and also increases the lifespan of the tooth.


   Conclusion Top


From the FEA analysis, it is evident that maximum stress was generated by “Metal Richmond crown” when compared to “PEEK Richmond crown.” Furthermore, surrounding the cortical and trabecular bones, the stress generated was least in “PEEK Richmond crown.” Hence, this study proves that “PEEK Richmond crown” can be used to restore endodontically treated teeth, generating least stress in the clinical approach for great success outcome.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Shetty PP, Meshramkar R, Patil KN, Nadiger RK. A finite element analysis for a comparative evaluation of stress with two commonly used esthetic posts. Eur J Dent 2013;7:419-22.  Back to cited text no. 1
  [Full text]  
2.
Asmussen E, Peutzfeldt A, Sahafi A. Finite element analysis of stresses in endodontically treated, dowel-restored teeth. J Prosthet Dent 2005;94:321-9.  Back to cited text no. 2
    
3.
Eid R, Juloski J, Ounsi H, Silwaidi M, Ferrari M, Salameh Z. Fracture resistance and failure pattern of endodontically treated teeth restored with computer-aided design/computer-aided manufacturing post and cores: A pilot study. J Contemp Dent Pract 2019;20:56-63.  Back to cited text no. 3
    
4.
Gogna R, Jagadish S, Shashikala K, Keshava Prasad B. Restoration of badly broken, endodontically treated posterior teeth. J Conserv Dent 2009;12:123-8.  Back to cited text no. 4
[PUBMED]  [Full text]  
5.
Vinothkumar TS, Kandaswamy D, Chanana P. CAD/CAM fabricated single-unit all-ceramic post-core-crown restoration. J Conserv Dent 2011;14:86-9.  Back to cited text no. 5
[PUBMED]  [Full text]  
6.
Panayotov IV, Orti V, Cuisinier F, Yachouh J. Polyetheretherketone (PEEK) for medical applications. J Mater Sci Mater Med 2016;27:118.  Back to cited text no. 6
    
7.
Patil DB, Reddy ER, Rani ST, Kadge SS, Patil SD, Madki P. Evaluation of stress in three different fiber posts with two-dimensional finite element analysis. J Indian Soc Pedod Prev Dent 2021;39:178-82.  Back to cited text no. 7
[PUBMED]  [Full text]  
8.
Mahmoudi M, Saidi A, Gandjalikhan Nassab SA, Hashemipour MA. A three-dimensional finite element analysis of the effects of restorative materials and post geometry on stress distribution in mandibular molar tooth restored with post-core crown. Dent Mater J 2012;31:171-9.  Back to cited text no. 8
    
9.
Srirekha A, Bashetty K. A comparative analysis of restorative materials used in abfraction lesions in tooth with and without occlusal restoration: Three-dimensional finite element analysis. J Conserv Dent 2013;16:157-61.  Back to cited text no. 9
[PUBMED]  [Full text]  
10.
Aslan T, Üstün Y, Esim E. Stress distributions in internal resorption cavities restored with different materials at different root levels: A finite element analysis study. Aust Endod J 2019;45:64-71.  Back to cited text no. 10
    
11.
Upadhyaya V, Bhargava A, Parkash H, Chittaranjan B, Kumar V. A finite element study of teeth restored with post and core: Effect of design, material, and ferrule. Dent Res J (Isfahan) 2016;13:233-8.  Back to cited text no. 11
    
12.
Kang N, Wu YY, Gong P, Yue L, Ou GM. A study of force distribution of loading stresses on implant-bone interface on short implant length using 3-dimensional finite element analysis. Oral Surg Oral Med Oral Pathol Oral Radiol 2014;118:519-23.  Back to cited text no. 12
    
13.
Narayanaswamy S, Meena N, Shetty A, Kumari A, Dn N. Finite element analysis of stress concentration in Class V restorations of four groups of restorative materials in mandibular premolar. J Conserv Dent 2008;11:121-6.  Back to cited text no. 13
[PUBMED]  [Full text]  
14.
Reinhardt RA, Krejci RF, Pao YC, Stannard JG. Dentin stresses in post-reconstructed teeth with diminishing bone support. J Dent Res 1983;62:1002-8.  Back to cited text no. 14
    
15.
Hsu ML, Chen CS, Chen BJ, Huang HH, Chang CL. Effects of post materials and length on the stress distribution of endodontically treated maxillary central incisors: A 3D finite element analysis. J Oral Rehabil 2009;36:821-30.  Back to cited text no. 15
    
16.
Cailleteau JG, Rieger MR, Akin JE. A comparison of intracanal stresses in a post-restored tooth utilizing the finite element method. J Endod 1992;18:540-4.  Back to cited text no. 16
    
17.
Eskitaşcioğlu G, Belli S, Kalkan M. Evaluation of two post core systems using two different methods (fracture strength test and a finite elemental stress analysis). J Endod 2002;28:629-33.  Back to cited text no. 17
    
18.
Barjau-Escribano A, Sancho-Bru JL, Forner-Navarro L, Rodríguez-Cervantes PJ, Pérez-Gónzález A, Sánchez-Marín FT. Influence of prefabricated post material on restored teeth: Fracture strength and stress distribution. Oper Dent 2006;31:47-54.  Back to cited text no. 18
    
19.
Coelho CS, Biffi JC, Silva GR, Abrahão A, Campos RE, Soares CJ. Finite element analysis of weakened roots restored with composite resin and posts. Dent Mater J 2009;28:671-8.  Back to cited text no. 19
    
20.
Değer Y, Adigüzel Ö, Yiğit Özer S, Kaya S, Seyfioğlu Polat Z, Bozyel B. Evaluation of temperature and stress distribution on 2 different post systems using 3-dimensional finite element analysis. Med Sci Monit 2015;21:3716-172.  Back to cited text no. 20
    
21.
Pegoretti A, Fambri L, Zappini G, Bianchetti M. Finite element analysis of a glass fibre reinforced composite endodontic post. Biomaterials 2002;23:2667-82.  Back to cited text no. 21
    

Top
Correspondence Address:
Dr. Subhabrata Maiti
Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jcd.jcd_638_20

Rights and Permissions


    Figures

  [Figure 1], [Figure 2]
 
 
    Tables

  [Table 1], [Table 2]

This article has been cited by
1 Dentists' Preference toward Fixed Versus Removable Implant Prosthesis on Edentulous Jaws to Improve Quality of Life
Sanjog Agarwal, V. Ashok, Subhabrata Maiti, Vatika Agarwal
Journal of Long-Term Effects of Medical Implants. 2023; 33(1): 83
[Pubmed] | [DOI]
2 Knowledge, Attitude, and Perception Regarding the Financial Aspects of Prosthetic Rehabilitation Using Dental Implants: A Double-Questionnaire-Based Study
Amrutha Shenoy, Dhanraj M. Ganapathy, Subhabrata Maiti, Vinay Sivaswamy
Journal of Long-Term Effects of Medical Implants. 2023; 33(3): 21
[Pubmed] | [DOI]
3 Evaluation of Peri-Implant Crestal Bone Loss with Different Implant Systems, Primary Stability, Bone Density and Soft Tissue Thickness: A Retrospective Study
Amrutha Shenoy, Subhasree Rohinikumar, Subhabrata Maiti, Vinay Sivaswamy, Vaishnavi Rajaraman
Journal of Long-Term Effects of Medical Implants. 2023; 33(4): 53
[Pubmed] | [DOI]
4 Factors Affecting the Accuracy of Intraoral Scanners-A Systematic Review
Senthamil Sindhu, Subhabrata Maiti, Deepak Nallaswamy
Annals of Dental Specialty. 2023; 11(1): 40
[Pubmed] | [DOI]
5 Assessment of Bone Turnover Markers Prior to Dental Implant Placement for Osteoporosis Patient- A Case- Control Study
Nirubama Karunakaran, Subhabrata Maiti, Selvaraj Jayaraman, Jessy Paulraj
Annals of Dental Specialty. 2023; 11(2): 57
[Pubmed] | [DOI]



 

Top
 
 
 
  Search
 
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Email Alert *
    Add to My List *
* Registration required (free)  
 


    Abstract
   Introduction
    Materials and Me...
   Results
   Discussion
   Conclusion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed1678    
    Printed92    
    Emailed0    
    PDF Downloaded70    
    Comments [Add]    
    Cited by others 5    