Aim: This study was conducted to evaluate the effect of preflaring and file size on the accuracy of the Root ZX and E-PEX Pro electronic apex locators (EALs). Materials and Methods: The actual working length was set 1 mm short of the apical foramen in the forty extracted mandibular premolars. The teeth were embedded in an alginate mold, and two examiners performed the electronic measurements using #10, #15, and #20 K-files. The files were inserted into the root canals until the “0.0” or “APEX” signals were observed on the light-emitting diode or display screens for the E-PEX Pro and Root ZX, respectively, retracting to the 1.0 mark. The measurements were repeated after the preflaring using the S1 and SX Pro-Taper instruments. The mean differences between the actual length and electronic length values were analyzed by the Wilcoxon signed-ranked test with a significance level of P < 0.05. The factors evaluated were “Accuracy of EALs,” “size of file,” and “presence of preflaring. Results: No significant differences were observed in the accuracy of both EALs when compared with the actual lengths. On the size of the file, significant difference noticed with #20 K-file. The preflaring procedure significantly (P < 0.05) increased the accuracy of the measurements for the Root ZX and Epex Pro. Conclusions: The tested EALs showed acceptable accuracy, whereas the preflaring procedure revealed a more significant effect than the used file size.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed222    
    Printed14    
    Emailed0    
    PDF Downloaded24    
    Comments [Add]    

Recommend this journal