Journal of Conservative Dentistry
Home About us Editorial Board Instructions Submission Subscribe Advertise Contact e-Alerts Login 
Users Online: 162
Print this page  Email this page Bookmark this page Small font sizeDefault font sizeIncrease font size
 


 
Table of Contents   
ORIGINAL RESEARCH ARTICLE  
Year : 2018  |  Volume : 21  |  Issue : 1  |  Page : 52-56
Resistance to fracture of teeth instrumented using novel EndoStar E5 rotary versus ProTaper NEXT and WaveOne file systems


1 Department of Conservative Dentistry and Endodontics, Nair Hospital Dental College, Mumbai, Maharashtra, India
2 Department of Conservative Dentistry and Endodontics, Government Dental College and Hospital, Mumbai, Maharashtra, India
3 Department of Dentistry, Sir H. N. Reliance Foundation Hospital, Mumbai, Maharashtra, India
4 Department of Surgical Sciences, College of Dentistry, Ajman University, Ajman, UAE

Click here for correspondence address and email

Date of Submission18-Aug-2016
Date of Decision28-Oct-2016
Date of Acceptance11-Dec-2017
Date of Web Publication19-Feb-2018
 

   Abstract 

Aim: The current study compared the fracture resistance of samples instrumented by two rotary files and a reciprocating file, obturated with gutta-percha and AH Plus.
Materials and Methods: A total of 60 freshly extracted mandibular premolar teeth with single roots and single canals were acquired and decoronated at or below the cementoenamel junction. The samples were randomly divided into four groups (n = 15). Group 1 control (noninstrumented/obturated), and for Groups 2–4 root canal instrumentation was done by EndoStar E5 (EE5), ProTaper NEXT (PTN), and WaveOne, respectively. Following instrumentation, the samples were obturated using gutta-percha cones and AH Plus sealer using lateral compaction. A week later, vertical load was applied to the specimen's canal in each group until fracture. The loads required for fracture were recorded and statistically analyzed.
Results: The mean loads required to fracture (Newton; N) for the four groups were; 388.54 (±29.93), 310.35 (±26.05), 328.40 (±20.67), and 278.54 (±34.16). The loads exhibited highly significant difference (P < 0.0001; analysis variance). The following Tukey's post hoc test confirmed, both samples in Groups 2 and 3 required similar loads for fracture (P > 0.05) and significantly higher than Group 4 (P < 0.01).
Conclusion: The samples instrumented by EE5 and PTN exhibit similar fracture resistance.

Keywords: EndoStar E5; fracture strength, instrumentation; ProTaper NEXT; WaveOne

How to cite this article:
Pawar AM, Pawar MG, Thakur B, Banga KS, Luke AM. Resistance to fracture of teeth instrumented using novel EndoStar E5 rotary versus ProTaper NEXT and WaveOne file systems. J Conserv Dent 2018;21:52-6

How to cite this URL:
Pawar AM, Pawar MG, Thakur B, Banga KS, Luke AM. Resistance to fracture of teeth instrumented using novel EndoStar E5 rotary versus ProTaper NEXT and WaveOne file systems. J Conserv Dent [serial online] 2018 [cited 2021 Jul 23];21:52-6. Available from: https://www.jcd.org.in/text.asp?2018/21/1/52/225741

   Introduction Top


Root canal instrumentation with motorized endodontic files results in weakening the dentin integrity, leading to a reduction in the fracture resistance of treated tooth.[1],[2],[3] This may also lead to a vertical root fracture (VRF) with extraction being the only treatment option left.[4],[5] Instruments used for root canal shaping have evolved from conventional 2% taper hand instruments to recently used rotary and reciprocating instruments with a greater taper (4%–9% taper).[6] As these files have a design, which incorporates increasing tapers, it results in the aggressive removal of the radicular dentin reducing the fracture strength.[4],[5],[7]

Another important factor is the stress generated on the radicular dentin when using endodontic instruments for shaping. The dentin's tensile strength is 106 MPa, but the currently used rotary files generate 311–368 MPa of stress on the radicular dentin, thus leading to the formation of micro-cracks.[8] The rotary files are associated with 18%–60% and the reciprocating files are associated with around three times more formation of micro-cracks in the radicular dentin when used for instrumentation.[6]

Lateral compaction with nickel-titanium spreader using gutta-percha cones and a sealer is the most commonly used technique for obturation as it results in less amount of force generated during the procedure.[4]

The current study aimed to compare the fracture resistance of teeth instrumented by a novel rotary file EndoStar E5 (EE5; Poldent Co. LTD., Warsaw, Poland), ProTaper NEXT (PTN; Dentsply Tulsa Dental, Tulsa, OK) and reciprocating WaveOne (WO; Dentsply Maillefer, Ballaigues, Switzerland) file systems after obturation.


   Materials and Methods Top


Freshly extracted mandibular premolar teeth with single straight root canals and completely formed apices were acquired and stored in saliva substitute at 37°C. The samples were sectioned at/below the cementoenamel junction using a diamond-coated bur under water cooling; leaving roots segments of 16 mm in length and examined with a stereomicroscope under ×10 magnification to detect any defects. Teeth with such findings were excluded and 75 teeth were selected for the current study.

The selected samples were scanned using cone beam computed tomography (CBCT; ProMax 3D Mid; Planmeca OY, Helsinki, Finland) to standardize the root canal shape (mesiodistal and buccolingual dimensions). For all the samples except the control group, a glide path was prepared till working length with a #20 k-file.

Instrumentation

Group 1 (Control)

The samples in this group remained untreated with no instrumentation and no filling.

Group 2 (EndoStar E5)

The samples were instrumented using EE5 rotary file system. File sizes; E5 1:size 30/0.08 taper; E5 2:size 30/0.06 taper; E5 3:size 30/0.04% taper; E5 4:size 25/0.04 taper and E5 5:size 20/0.04 taper [Figure 1]a. The files were operated at 300 rpm with torque a setting of 2.5 Ncm using Xsmart Plus (Dentsply Maillefer, Ballaigues, Switzerland). The canal orifices of the samples were flared using E5 1 instrumenting the coronal 3rd. The canals were recapitulated and the E5 2 and E5 3 in the sequence were advanced few millimeters deeper than E5 1. Using the E5 4 till working length followed this. Before introducing a new file, the root canal was irrigated with 3 ml of 5.25% sodium hypochlorite (NaOCl) and recapitulated with a #15 K-file, and then, the subsequent file was introduced. Ethylenediaminetetraacetic acid (EDTA) paste (RC Help, Prime Dental Products, Mumbai, India) was used as lubricant for the file with every reinsertion.
Figure 1: (a) The entire sequence of novel EndoStar E5 rotary file system comprising of five files. (b) The modified “S” shaped cross-section of the file exhibiting the two-point contact at an angle of 90°

Click here to view


Group 3 (ProTaper NEXT)

Samples were instrumented by PTN rotary files (X1; 20/0.04 taper and X2; 25/0.06 taper), using a gentle in-and-out motion with Xsmart Plus (Dentsply Maillefer) at 300 rpm and a torque of 2.6 Ncm. The root canal orifices were flared using Sx (Dentsply Tulsa Dental). The PTN X1 and X2 files were used in an outward brushing motion following coronal flaring. On meeting obstruction in the canal, the file was withdrawn, the canal was irrigated, recapitulated by #15 k-file and the file was reintroduced into the canal. The instrumentation was carried out in the above manner till the X1 and X2 both reached the working length. The irrigation protocol during instrumentation using this file was similar to Group 2.

Group 4 (WaveOne)

The WO (primary; 25, 0.08% taper; Dentsply Maillefer) reciprocating single file system was used to instrument the samples in this group. The root canal orifices were flared using Sx as done in Group 3. Following flaring, the WO files were used in pecking motion with Xsmart Plus (Dentsply Maillefer). On meeting obstruction the file was removed, the canal was irrigated, recapitulated by #15 k-file and the file was reintroduced into the canal. The instrumentation was continued in the above manner till the file reached working length.

Final irrigation protocol for Groups 2–4

After completion of instrumentation, a final flush was performed using 5 mL of 17% aqueous EDTA (Dent Wash, Prime Dental Products) for 1 min and 5 mL of 5.25% NaOCl for 1 min followed by the final rinse with 5 mL of distilled water.

Obturation

After instrumentation (Groups 2–4), the canals were dried with sterile paper points and master gutta-percha cones confirmed radiographically, were selected. The dentinal wall was then coated with AH plus sealer (Dentsply DeTrey, Konstanz, Germany) using a lentulo spiral, followed by placing the master-cone, and adding accessory cones using a #25 Ni-Ti finger spreader. Excess gutta-percha was sheared off using a hot hand plugger, access cavities were filled with composite resin and sealer was allowed to set for 7 days at 37°C and 100% humidity.

Fracture testing

The samples were covered with wax obtaining 0.2–0.3 mm thickness of layer (apical 5 mm). Further, samples were mounted in copper rings with height of 25 mm and a diameter of 15 mm and filled with self-cure acrylic resin, exposing 9 mm of the coronal part. Once the polymerization started, the roots were removed and the wax was cleaned off, followed by coating them with a thin layer of polyvinyl siloxane impression material and embedding again into acrylic resin.

The acrylic blocks were then placed on the universal testing machine (Instron Corp, Canton, MA, USA). The tip with a diameter of 3 mm was used. The tip was centered over the canal orifice, and a gradually increasing vertical force was exerted (1 mm/min) until fracture. The maximum force required to fracture each sample was recorded in Newton (N).

Statistical analysis

The fracture loads required for Groups 1–4 were analyzed using one-way analysis variance (ANOVA) followed by Tukey's post hoc test for multiple. The abovementioned tests were performed using Statistical Package for the Social Sciences (SPSS) software version 20 (SPSS Inc., Chicago, IL, USA).


   Results Top


The mesiodistal and buccolingual dimensions for the samples in four groups were similar (P = 0.579 and P = 0.762; one-way ANOVA), respectively. The mean load required to fracture in 4 groups were 388.54 (±29.93), 310.35 (±26.05), 328.40 (±20.67), and 278.54 (±34.16) for Groups 1–4, respectively. The loads acquired exhibited a significant difference (P< 0.01; one-way ANOVA). Intergroup analysis (Tukey's post hoc test) revealed that samples in Groups 2 (EE5) and 3 (PTN) to be similar (P > 0.05) in fracture resistance. Furthermore, samples in Group 5 (WO) exhibited significantly less fracture resistance (P< 0.01) [Table 1] and [Table 2].
Table 1: Mean and standard deviation for the loads required for the fracture of the samples in Newton (N) for control and the instrumented groups

Click here to view
Table 2: Post hoc test results for inter group comparison for the groups tested

Click here to view



   Discussion Top


Root canal therapy results in weakening of the tooth, after shaping and cleaning of its root canal and almost 30% reduction in the vertical fracture resistance. Various causes of VRFs have been proposed in literature and root canal instrumentation is one of them.[4],[9] The results of the current study indicate that the fracture resistance of endodontically treated tooth was reduced as compared to the control group. It has been reported that root canal instrumentation using rotary files or reciprocating files reduces the fracture resistance of tooth, with the reciprocating files reducing it to a higher extent.[4],[5],[10] In the current study, the samples instrumented with reciprocating WO file exhibited the least fracture resistance in groups tested.

In such in vitro studies, which undertake mechanical tests, the standardization of the samples being tested is the most important factor of such studies. The extraction time and storing conditions, variation in the length of the roots, shape of the root canals and volume of the root canal space generally affect the results of such studies.[11] To eliminate these discrepancies in the current study, the samples tested were scanned preoperatively using CBCT to measure and use samples with similar mesiodistal and buccolingual dimensions. Furthermore, the working lengths of the root segments were maintained at 16 mm for all the samples.

The rotary/reciprocating files result in formation of dentinal micro-cracks. These files possess varying percentages of taper (0.06%–0.09%), which may contribute to the dentinal micro-crack formation.[2],[5] These micro-cracks have been reportedly observed at levels ranging from the coronal third to the apical third of the roots instrumented and also become high-stress concentration areas and the crack can gradually propagate to the root canal surface, a root cause for VRFs.[2],[4],[5],[9],[12],[13]

The presence of excessive taper results in unnecessary removal of root dentin. The PTN rotary files are designed with an unusual design where the center of mass and the center of rotation are offset when this file is in the rotation. This unique pattern aids in an increased cross-sectional space for better cutting, loading, and auguring debris coronally. This pattern also helps in minimizing the dentin engagement, thus producing less stress on the radicular dentin. These files exhibit an alternating (increasing and decreasing) percentage tapers (X1; 0.04 and X2; 0.06). Less micro-cracks are associated with these files is reported, which was attributed to swaggering motion (alternating taper), decreasing the screwing effect, by minimizing the contact between the file and the dentin.[14] In addition, these files are manufactured using M-wire alloy, which exhibits more flexibility than nickel-titanium (NiTi).[15],[16],[17] Pawar et al., in a recent study reported better fracture resistance of samples instrumented with PTN compared to WO.[4]

The WO files are characterized by a convex triangular or modified triangular cross-section resulting in a low cutting efficiency and less chip space. The reciprocal motion also enhances debris transportation towards the apical third and result in increased torsional forces. WO files cause significantly more micro-cracks than a full sequence of rotary files, also these cracks are seen more at the apical level, which may result in less fracture resistance exhibited by the teeth in the group instrumented by WO files in the present study.[4],[18] Bürklein et al. in their study reported that this newer generation reciprocating instrument, WO caused significantly more micro-cracks than a full sequence of rotary files.[18] The WO primary files have a taper of 0.08 and a tip diameter of 0.25. However, the PTN X2 file has a taper of 0.06 and E5 has 0.004 taper for the apical size of 0.25. Thus, we believe that the larger taper sizes of the WO primary instruments could result in more cracks thus reducing the fracture resistance of the teeth instrumented.[19] Although with the reciprocating movement, flexural and torsional stresses acting on the dentin are reduced, using a single file to enlarge the canal, regardless of the preexisting conditions of the canal and large taper of the WO file could still result in the formation of more dentinal defects.[20],[21],[22] Furthermore, stiffer file designs generate higher stress during shaping, which raises the risk of dentinal defects that may lead to apical root cracking.[8]

To the best of the authors' knowledge, till date fracture resistance exhibited by the teeth instrumented using novel EE5 rotary files is yet to be reported in the literature. TThe Endostar E5 rotary files [Figure 1]a have a cross section similar to the Mtwo files.[23] These files are manufactured using NiTi alloy, having a cross-sectional design of the modified shape of the letter “S” with a two-point contact at 90°s [Figure 1]b, making the file more aggressive. Hin et al., confirmed that the rotary files have an active rotary movement of and can cause high-stress concentration resulting in crack formation, which results in a reduction of fracture resistance of the instrumented teeth.[24],[25] In the current study, there was no significant difference between the samples instrumented using rotary files.


   Conclusion Top


Within the limitations of the current study, it can be concluded that the teeth instrumented by the novel EE5 rotary file system exhibit better fracture resistance than those instrumented using WO reciprocating file system. Furthermore, the teeth group instrumented with EE5 did not differ when compared to those instrumented using PTN. Further investigation is required addressing the issue of micro-crack formation in teeth instrumented using EE5.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
   References Top

1.
Shemesh H, Bier CA, Wu MK, Tanomaru-Filho M, Wesselink PR. The effects of canal preparation and filling on the incidence of dentinal defects. Int Endod J 2009;42:208-13.  Back to cited text no. 1
    
2.
Yoldas O, Yilmaz S, Atakan G, Kuden C, Kasan Z. Dentinal microcrack formation during root canal preparations by different NiTi rotary instruments and the self-adjusting file. J Endod 2012;38:232-5.  Back to cited text no. 2
    
3.
Fuss Z, Lustig J, Tamse A. Prevalence of vertical root fractures in extracted endodontically treated teeth. Int Endod J 1999;32:283-6.  Back to cited text no. 3
    
4.
Pawar AM, Pawar SM, Pawar MG, Kokate SR. Fracture resistance of teeth instrumented by the self-adjusting file, ProTaper NEXT and WaveOne. J Pierre Fauchard Acad 2014;28:83-7.  Back to cited text no. 4
    
5.
Pawar AM, Barfwala D, Pawar M, Metzger Z, Kfir A, Jain N. Assessment of the fracture resistance of teeth instrumented using 2 rotary and 2 reciprocating les versus the Self-Adjusting File (SAF): An ex vivo comparative study on mandibular premolars. J Conserv Dent 2016;19:138-42.  Back to cited text no. 5
[PUBMED]  [Full text]  
6.
Haapasalo M, Shen Y. Evolution of nickel-titanium instruments: From past to future. Endod Top 2013;29:3-17.  Back to cited text no. 6
    
7.
Capar ID, Altunsoy M, Arslan H, Ertas H, Aydinbelge HA. Fracture strength of roots instrumented with self-adjusting file and the ProTaper rotary systems. J Endod 2014;40:551-4.  Back to cited text no. 7
    
8.
Kim HC, Lee MH, Yum J, Versluis A, Lee CJ, Kim BM, et al. Potential relationship between design of nickel-titanium rotary instruments and vertical root fracture. J Endod 2010;36:1195-9.  Back to cited text no. 8
    
9.
Liu R, Hou BX, Wesselink PR, Wu MK, Shemesh H. The incidence of root microcracks caused by 3 different single-file systems versus the ProTaper system. J Endod 2013;39:1054-6.  Back to cited text no. 9
    
10.
Wu MK, van der Sluis LW, Wesselink PR. Comparison of mandibular premolars and canines with respect to their resistance to vertical root fracture. J Dent 2004;32:265-8.  Back to cited text no. 10
    
11.
Cobankara FK, Ungör M, Belli S. The effect of two different root canal sealers and smear layer on resistance to root fracture. J Endod 2002;28:606-9.  Back to cited text no. 11
    
12.
Lertchirakarn V, Palamara JE, Messer HH. Load and strain during lateral condensation and vertical root fracture. J Endod 1999;25:99-104.  Back to cited text no. 12
    
13.
Adorno CG, Yoshioka T, Jindan P, Kobayashi C, Suda H. The effect of endodontic procedures on apical crack initiation and propagation ex vivo. Int Endod J 2013;46:763-8.  Back to cited text no. 13
    
14.
Capar ID, Arslan H, Akcay M, Uysal B. Effects of ProTaper universal, ProTaper next, and HyFlex instruments on crack formation in dentin. J Endod 2014;40:1482-4.  Back to cited text no. 14
    
15.
Pereira ES, Peixoto IF, Viana AC, Oliveira II, Gonzalez BM, Buono VT, et al. Physical and mechanical properties of a thermomechanically treated NiTi wire used in the manufacture of rotary endodontic instruments. Int Endod J 2012;45:469-74.  Back to cited text no. 15
    
16.
Peters OA, Morgental RD, Schulze KA, Paqué F, Kopper PM, Vier-Pelisser FV, et al. Determining cutting efficiency of nickel-titanium coronal flaring instruments used in lateral action. Int Endod J 2014;47:505-13.  Back to cited text no. 16
    
17.
Capar ID, Ertas H, Ok E, Arslan H, Ertas ET. Comparative study of different novel nickel-titanium rotary systems for root canal preparation in severely curved root canals. J Endod 2014;40:852-6.  Back to cited text no. 17
    
18.
Bürklein S, Tsotsis P, Schäfer E. Incidence of dentinal defects after root canal preparation: Reciprocating versus rotary instrumentation. J Endod 2013;39:501-4.  Back to cited text no. 18
    
19.
Karataş E, Gündüz HA, Kırıcı DÖ, Arslan H, Topçu MÇ, Yeter KY, et al. Dentinal crack formation during root canal preparations by the twisted file adaptive, ProTaper next, ProTaper universal, and WaveOne instruments. J Endod 2015;41:261-4.  Back to cited text no. 19
    
20.
Li SH, Lu Y, Song D, Zhou X, Zheng QH, Gao Y, et al. Occurrence of dentinal microcracks in severely curved root canals with ProTaper universal, WaveOne, and ProTaper next file systems. J Endod 2015;41:1875-9.  Back to cited text no. 20
    
21.
Pedulla E, Grande NM, Plotino G, et al. Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel-titanium rotary instruments. J Endod 2013;39:258–61.  Back to cited text no. 21
    
22.
Prichard J. Rotation or reciprocation: A contemporary look at NiTi instruments? Br Dent J 2012;212:345-6.  Back to cited text no. 22
    
23.
Dobó-Nagy C, Serbán T, Szabó J, Nagy G, Madléna M. A comparison of the shaping characteristics of two nickel-titanium endodontic hand instruments. Int Endod J 2002;35:283-8.  Back to cited text no. 23
    
24.
West JD. Introduction of a new rotary endodontic system: Progressively tapering files. Dent Today 2001;20:50-2, 54-7.  Back to cited text no. 24
    
25.
Hin ES, Wu MK, Wesselink PR, Shemesh H. Effects of self-adjusting file, Mtwo, and ProTaper on the root canal wall. J Endod 2013;39:262-4.  Back to cited text no. 25
    

Top
Correspondence Address:
Dr. Ajinkya M Pawar
Y-10/155, Government Colony, Bandra East, Mumbai - 400 051, Maharashtra
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/JCD.JCD_216_16

Rights and Permissions


    Figures

  [Figure 1]
 
 
    Tables

  [Table 1], [Table 2]



 

Top
 
 
 
  Search
 
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Email Alert *
    Add to My List *
* Registration required (free)  
 


    Abstract
   Introduction
    Materials and Me...
   Results
   Discussion
   Conclusion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed1709    
    Printed19    
    Emailed0    
    PDF Downloaded172    
    Comments [Add]    

Recommend this journal