ORIGINAL RESEARCH ARTICLE |
|
Year : 2017 | Volume
: 20
| Issue : 5 | Page : 322-325 |
|
Apical extrusion of debris during root canal preparation using a novel nickel-titanium file system: WaveOne gold
Asiye Nur Dincer, Mehmet Burak Guneser, Dilara Arslan
Department of Endodontics, Faculty of Dentistry, Bezmialem Vakif University, Istanbul, Turkey
Correspondence Address:
Dr. Asiye Nur Dincer Department of Endodontics, Faculty of Dentistry, Bezmialem Vakif University, Istanbul, 34093 Turkey
 Source of Support: None, Conflict of Interest: None  | Check |
DOI: 10.4103/JCD.JCD_407_16
|
|
Aim: This study was intended to evaluate the amount of apically extruded debris following root canal preparation with three different instrumentation systems.
Materials and Methods: Sixty mandibular incisor teeth were selected and randomly divided into three groups (n = 20/group) according to the instrumentation system used: the ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland), the Twisted File Adaptive (TFA; SybronEndo, Orange, CA, USA), and the WaveOne Gold (WOG; Dentsply Maillefer, Ballaigues, Switzerland). All apically extruded debris was collected and dried in preweighed glass vials. The mean weight of the apically extruded debris was obtained using a microbalance. The time for root canal preparation was also recorded. The data were analyzed using a one-way analysis of variance.
Results: The mean weights of apically extruded debris were 0.00035 ± 0.00014 g (PTN); 0.00023 ± 0.0001 g (TFA); and 0.00019 ± 0.0001 g (WOG) (P < 0.01). The mean preparation time value was 301,13 ± 62.14 s (PTN); 234.27 ± 34.88 s (TFA); and 239.8 ± 58.6 s (WOG) (P < 0.05).
Conclusions: The PTN system extruded more debris than the TFA and WOG systems. The TFA and WOG systems were faster than the PTN system. |
|
|
|
[FULL TEXT] [PDF]* |
|
 |
|