Journal of Conservative Dentistry
Home About us Editorial Board Instructions Submission Subscribe Advertise Contact e-Alerts Login 
Users Online: 28
Print this page  Email this page Bookmark this page Small font sizeDefault font sizeIncrease font size
ORIGINAL RESEARCH ARTICLE
Year : 2017  |  Volume : 20  |  Issue : 4  |  Page : 251-254

A comparative evaluation of accuracy of three electronic apex locators using histological section as gold standard: An ex vivo study


Department of Conservative Dentistry and Endodontics, College of Dental Science and Hospital, Indore, Madhya Pradesh, India

Correspondence Address:
Divya Saxena
Department of Conservative Dentistry and Endodontics, College of Dental Science and Hospital, F-12, Jhoomer Ghat, Rau, Indore - 453 331, Madhya Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/JCD.JCD_175_16

Rights and Permissions

Introduction: The aim of the present study was to comparatively evaluate the accuracy of iRoot, iPex II, and Propex pixi apex locator using histological sections as the gold standard. Materials and Methods: Thirty patients indicated for extraction of single-rooted permanent teeth with single canal system were selected. Working lengths (WLs) of teeth were determined using iRoot, iPex II, and Propex pixi. Teeth were then extracted, and the files were reintroduced to the anatomic apex to measure anatomic canal length (ACL) and fixed at the ACL using flowable composite. The apical 4 mm of the roots were longitudinally shaved away to visualize the canal under a stereomicroscope at ×24 magnification. Digital photographs were evaluated to measure the distance between the major diameter and minor diameter. Thus, the WL, that is, the minor diameter length (MDL) was ascertained. Results: Measurements of mean WLs within ±0.5 mm of minor diameter were 90% acceptable for iRoot, 86.66% for iPex II, and 80% for Propex pixi when compared with mean MDL as obtained from the histological sections. Conclusions: All apex locators have been shown to produce acceptable level of accuracy which clearly indicates their reliability in determining the WL.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1537    
    Printed30    
    Emailed0    
    PDF Downloaded166    
    Comments [Add]    

Recommend this journal