Journal of Conservative Dentistry
Home About us Editorial Board Instructions Submission Subscribe Advertise Contact e-Alerts Login 
Users Online: 2744
Print this page  Email this page Bookmark this page Small font sizeDefault font sizeIncrease font size
 

 
Table of Contents   
ORIGINAL ARTICLE  
Year : 2012  |  Volume : 15  |  Issue : 3  |  Page : 270-273
Effect of saliva and blood contamination on the bond strength of self-etching adhesive system- An in vitro study


1 Department of Conservative Dentistry and Endodontics, Narayana Dental College and Hospital, Nellore, India
2 Department of Conservative Dentistry and Endodontics, Drs. Sudha & Nageswara Rao Siddhartha Institute of Dental Sciences, Chinaoutpalli, Gannavaram, A. P., India

Click here for correspondence address and email

Date of Submission10-Jan-2012
Date of Decision19-Mar-2012
Date of Acceptance28-Mar-2012
Date of Web Publication3-Jul-2012
 

   Abstract 

Aim: The aims of this study were to determine the effect of saliva and blood contamination on the shear bond strength of self-etching adhesive to enamel and dentin; and, to compare the difference in bond strength due to contamination beforeand after application of the self-etch adhesive.
Materials and Methods: 40 human mandibular molars were wet ground on both buccal and lingual surfaces to prepare flat superficial enamel and dentin surfaces. They were randomly divided into two groups (n = 40) based on the substrate (enamel and dentin). Each group was further divided into five subgroups (n = 8) based on the type of contamination it was subjected to, and the step in the bonding sequence when the contamination occurred (before or after adhesive application). Fresh saliva and fresh human blood were applied either before or after the application of Xeno III® self-etching adhesive system (SES). Composite resin was applied as inverted, truncated cured cones that were subjected to shear bond strength test.
Statistical Analysis: One-way analysis of variance (ANOVA) and Tukey's Honestly Significant Difference (HSD) test were used.
Results: Statistically significant reduction in the bond strength was shown after both saliva and blood contamination before and after Xeno III® application (P< 0.05). Bond strength is significantly reduced after contamination with blood as compared to saliva.
Conclusions: When self-etching adhesive systems are used, saliva and blood contamination significantly decrease the bond strength of the adhesive to enamel and dentin of the tooth.

Keywords: Blood contamination; Dentin; Enamel; Saliva contamination; Self-etching adhesive; Shear bond strength

How to cite this article:
Koppolu M, Gogala D, Mathew VB, Thangala V, Deepthi M, Sasidhar N. Effect of saliva and blood contamination on the bond strength of self-etching adhesive system- An in vitro study. J Conserv Dent 2012;15:270-3

How to cite this URL:
Koppolu M, Gogala D, Mathew VB, Thangala V, Deepthi M, Sasidhar N. Effect of saliva and blood contamination on the bond strength of self-etching adhesive system- An in vitro study. J Conserv Dent [serial online] 2012 [cited 2023 Oct 4];15:270-3. Available from: https://www.jcd.org.in/text.asp?2012/15/3/270/97956

   Introduction Top


The increasing demand for esthetic restorations has generated intensive research of adhesive materials. Successful adhesion to dental hard tissues is a fundamental requirement prior to the insertion of resin based composites. [1],[2],[3] Any contamination of the prepared surface by saliva, blood or gingival crevicular fluid should be avoided in order to achieve a successful and durable bond between the resin composite and the tooth. [4],[5] Achieving good moisture control is a common problem encountered in restorative dentistry, especially when rubber dam isolation is not feasible. [2],[6] Many carious lesions are found in areas where it is difficult to obtain appropriate isolation for the use of dentin bonding agents, especially when the site is near or at the gingival margin. [2] Contemporary adhesive systems can be classified into two groups: total-etching and self-etching systems. [5]

Self-etching adhesives are commonly employed for bonding procedures, as they are user friendly and yield good clinical results. [4],[7] Several recent studies suggested that self-etch adhesives may be more resistant to salivary contamination because hydrophilic adhesive solutions, specifically products with acetone or ethanol based, may displace or diffuse through the salivary film to reach the underlying hydroxyapatite or collagen. [2],[4],[8] However, the effect of blood contamination on the adhesive properties of 1-step self-etching adhesives has not been fully understood. [2],[4],[9],[10] The aims of this present in vitro study were to determine the effect of saliva and blood contamination on shear bond strength of self-etching adhesive to enamel and dentin, and to compare the difference in bond strengths due to contamination before and after application of self-etch adhesive.


   Materials and Methods Top


40 freshly extracted non- carious human mandibular molars were stored in distilled water containing 0.2% thymol solution and used for the study. The teeth were cleaned using an ultrasonic cleaner and mounted in self curing acrylic resin. Samples were wet ground on both buccal and lingual surfaces using a series of silicon carbide discs to prepare flat superficial enamel and dentin surfaces. They were randomly divided into two groups (n = 40) based on the substrate as follows: Group I - enamel and Group II - dentin. Each group was further randomly divided into five subgroups (n = 8) based on the type of contamination subjected to, and the step in the bonding sequence when contamination occurred, that is, before or after adhesive application.

A commercially available self-etching adhesive Xeno III® (De Trey Dentsply, Germany) was used for the study [Table 1]. Fresh unstimulated saliva from the oral cavity and fresh human blood from the fingertip of one of the investigators was collected at the same time that the specimens were prepared for the study.
Table 1: Manufacturers, composition and application procedure of Xeno III® in the study

Click here to view


  • Control group (E and D: n = 8): In this group, the specimens were not subjected to either saliva or blood contamination. Self-etching adhesive was applied to the enamel and dentin of each specimen according to the manufacturer's instructions.
  • Contamination group 1 (E1 and D1: n = 8): Enamel and dentin surfaces were subjected to contamination with saliva for 15 seconds using a micro brush. After the contamination, the surfaces were rinsed for 10 seconds with water steam from an air-water syringe, followed by a gentle blast of air for 10 seconds to dry the surface. The self-etching adhesive was applied in the same manner as the control group.
  • Contamination group 2 (E2 and D2: n = 8): The same procedure as in group 1 was followed here, and the specimens were subjected to contamination with blood.
  • Contamination group 3 (E3 and D3: n = 8): The self-etching adhesive was applied to both enamel and dentin as in the control group. The surfaces were then subjected to contamination with saliva for 15 seconds, and then rinsed and dried as in group 1.
  • Contamination group 4 (E4 and D4: n = 8): The same procedure as in group 3 was followed except that the specimens were subjected to contamination with blood.


[Table 2] and [Figure 1] represent the groups and a summary of the experimental protocol, respectively.
Table 2: Experimental groups and protocol of the study

Click here to view
Figure 1: Schematic representation of the experimental protocol

Click here to view


A 3 mm diameter polytetrafluoroethylene mold was used to create an inverted, and truncated cone of composite (Filtek Z-250® , shade A1 - 3M ESPE, U.S.A.). The composite was inserted in two sections, and each one was photocured for 20 seconds (Bluephase C5® , Ivoclar-Vivadent AG, Liechtenstein). All specimens were stored at 37 °C in water for 24 hours before testing, to simulate oral environment. After storage, the specimens were transferred to the universal testing machine individually, and then subjected to shear bond strength analysis at a crosshead speed of 1.0 mm/minute at the Bangalore Integrated System Solutions (P) Ltd (BiSS), Bengaluru, Karnataka. Bond strengths were expressed in MPa.


   Results Top


The data obtained in the present study was subjected to statistical analysis using One-way analysis of variance (ANOVA), followed by Tukey's honestly significant difference (HSD) test. Regarding the enamel groups, the one-way ANOVA was performed to compare all experimental groups with the control, and a statistically sig­nificant difference between the tested groups was detected (F = 105.785 and P< 0.05). Tukey΄s multiple comparisons test between subgroups showed that E4 showed a statistically signifi­cant difference in bond strength when compared to the other experimental groups [Table 3]. Regarding the dentin groups, one-way ANOVA also detected a statistically significant difference be­tween the tested groups (F = 58.239 and P< 0.05). Tukey΄s multiple comparisons test between subgroups showed that D4 showed a statistically signifi­cant difference in bond strength when compared to the other experimental groups. Groups D1 and D3 showed no significant difference due to contamination on dentin either with saliva or blood before application of adhesive [Table 3]. It was observed that contaminated groups which were subjected to rinse and dry treatment before adhesive application showed higher shear bond strength values than after adhesive application.
Table 3: Shear bond strengths for tested groups (Mean ± Standard Deviation, MPa) in the study

Click here to view



   Discussion Top


Saliva and blood are two common contaminants that can affect the prepared tooth surface during placement of adhesives in restorative dental treat­ment. This study was designed to investigate their effect during different stages in the application of a self-etch adhesive.Self-etching adhesive systems have become very popular with clinicians due to the "no-rinse" concept and reduced post-operative sensitivity. Acid etching is not required; therefore, the problem of over-drying or over wetting the dentin is eliminated. This reduces the potential for post-operative sensitivity and bonding problems associated with movement of dentinal fluid through the patent dentinal tubules. The technique-sensitivity associated with bonding to a dehydrated collagen matrix is also eliminated. Self-etching adhesive systems provide a faster application due to a reduced number of components and application steps. [2],[4],[10],[11],[12] Self-etching adhesives systems may be classified into mild, moderate and strong, based on their pH, and, consequently, their ability to dissolve the smear layer and demineralize the underlying dentin. [13],[14] Xeno III® , an intermediary strong single step self-etch adhesive with an acidic pH of 1.4, has shown better micromechanical interlocking to enamel and dentin when compared to mild self-etch adhesives. [2],[15],[16] In this study, to simulate gingival bleeding in a laboratory setting, freshly drawn blood was used as the contaminant. Also, studies in literature search have shown that [2],[9],[10] the addition of an anticoagulant may decrease the bond strength.

Enamel results of this study reveal that saliva and blood contamination prior to the application of an adhesive showcomparatively higher bond strength values than contamination after adhesive application. The single bottle adhesives contain solvents such as ethanol and acetone that seem to denature the glycoprotein sugars, and remove the salivary contamination. [6] Xeno III® containing ethanol might have exerted this effect. Another explanation for this result is that the application of self-etch primer cleans or hydrolyzes blood on the enamel surface.[17]The present study showed a slight reduction in the shear bond strength values when contaminated with saliva after light curing of the adhesive, which was statistically significant. This could be due to the adsorption of glycoproteins onto the poorly polymerized adhesive surface, which results in oxygen inhibition. [15],[18] The result of the present study is in agreement with the result of an earlier study done by Fritzet al.using a one-step adhesive, which concluded that in a one bottle adhesive system, any contamination of the already cured adhesive layer seriously compromises the bond strength. [8],[15] Hitmi and others also reported that salivary contamination of the cured adhesive layer decreased shear bond strength dramatically. [19]

Blood contamination after light curing of Xeno III® resulted in the most significant decrease of shear bond strength compared to saliva contamination, which is in accordance with the findings of other authors. [4],[6],[10] Remnants of blood proteins which were not completely removed, could have impaired adhesion between the layers of adhesive and composite. In addition, rinsing of contaminant after adhesive application could have disrupted the oxygen-inhibited and unpolymerized layer. [2],[10],[20] Our dentin results also showed significantly reduced bond strengths when contamination was done after light curing of self-etching adhesive. Dentin contamination prior to application of bonding agent by both saliva and blood showed almost similar bond strength values. The influence of blood contamination on bond strength to dentin can be attributed to its macromolecules such as fibrinogen and platelets, which can form a film on the dentin surface which was also confirmed by Barakat and Powers. [21]

When contamination occurred following light curing of the adhesive, there is statistically significant decrease in shear bond strength. This was in agreement with the results of the study done by Fritz et al.[8] using one bottle adhesive systems, which concluded that any contamination of the already cured adhesive layer seriously compromised the bond strength. They put forward mainly three different hypotheses for the reduction in shear bond strength values:

  • Adsorption of glycoproteins to the poorly polymerized adhesive surface, thus preventing adequate co-polymerization;
  • compromise of the co-polymerization with the subsequent resin layer, by removal of the oxygen inhibited un-polymerized surface layer, during rinsing and drying; insufficient filling of the collagen mesh with resin. [8],[15]
  • Adhesive application after rinsing and drying of contaminants showed better bond strength. This is because cleaning procedure was able to remove the contaminants from tooth surface andalso render a better adhesion, which is in agreement with the results obtained by many studies. [2],[4],[6],[10],[15],[18]
  • The current study has several limitations, one being that the bond strength after reapplication of an adhesive after rinsing and drying of contaminant and before the composite restoration, was not studied. Other limitation is that the bond failure by microscopic means was not studied. The need for further studies with a better experimental design and using different types of adhesives is felt.



   Conclusions Top


Within the scope of the current study, the following conclusions were drawn:

  • Both blood and saliva contamination significantly decreased the shear bond strength, before and after application of Xeno III® on both the enamel and dentin.
  • Blood contamination decreased the bond strength more than saliva.
  • Both contaminants showed decrease in the bond strength more after adhesive application, than before.
  • Prevention of contamination is critical for good adhesion even in self-etching adhesive systems which have been designed to be less technique sensitive.


 
   References Top

1.Eick JD, Cobb CM, Chappell RP, Spencer P, Robinson SJ. The dentinal surface: Its influence on dentinal adhesion. Part I. Quintessence Int1991;22:967-77.  Back to cited text no. 1
[PUBMED]    
2.Yoo HM, Pereira PN. Effect of blood contamination with 1-step self-etching adhesives on microtensile bond strength to dentin. Oper Dent2006;31:660-5.  Back to cited text no. 2
[PUBMED]  [FULLTEXT]  
3.Jiang Q, Pan H, Liang B, Fu B, Hannig M. Effect of saliva contamination and decontamination on bovine enamel bond strength of four self-etching adhesives.Oper Dent 2010;35:194-202.  Back to cited text no. 3
    
4.Chang SW, Cho BH, Lim RY, Kyung SH, Park DS, Oh TS, et al. Effects of blood contamination on microtensile bond strength to dentin of three self-etch adhesives. Oper Dent 2010;35:330-6.  Back to cited text no. 4
[PUBMED]  [FULLTEXT]  
5.Kuphasuk W, Harnirattisai C, Senawongse P, Tagami J. Bond strengths of two adhesive systems to dentin contaminated with a hemostatic agent. Oper Dent 2007;32:399-405.  Back to cited text no. 5
[PUBMED]  [FULLTEXT]  
6.Eiriksson SO, Pereira PN, Swift EJ Jr, Heymann HO, Sigurdsson A. Effects of saliva contamination on resin-resin bond strength. Dent Mater 2004;20:37-44.  Back to cited text no. 6
[PUBMED]  [FULLTEXT]  
7.Kiremitçi A, Yalçin F, Gökalp S. Bonding to enamel and dentin using self-etching adhesive systems. Quintessence Int 2004;35:367-70.  Back to cited text no. 7
    
8.Fritz UB, Finger WJ, Stean H. Salivary contamination during bonding procedures with a one-bottle adhesive system. Quintessence Int 1998;29:567-72.  Back to cited text no. 8
    
9.Dietrich T, Kraemer ML, Roulet JF. Blood contamination and dentin bonding--effect of anticoagulant in laboratory studies. Dent Mater 2002;18:159-62.  Back to cited text no. 9
    
10.de Carvalho Mendonça EC, Vieira SN, Kawaguchi FA, Powers J, Matos AB. Influence of blood contamination on bond strength of a self-etching system. Eur J Dent 2010;4:280-6.  Back to cited text no. 10
    
11.Peumans M, Kanumilli P, De Munck J, Van Landuyt K, Lambrechts P, Van Meerbeek B. Clinical effectiveness of contemporary adhesives: A systematic review of current clinical trials. Dent Mater 2005;21:864-81.  Back to cited text no. 11
    
12.Akimoto N, Takamizu M, Momoi Y. 10-year clinical evaluation of a self-etching adhesive system. Oper Dent 2007;32:3-10.  Back to cited text no. 12
    
13.Tay FR, Pashley DH. Aggressiveness of contemporary self-etching systems. I: Depth of penetration beyond dentin smear layers. Dent Mater 2001;17:296-308.  Back to cited text no. 13
    
14.Chersoni S, Suppa P, Grandini S, Goracci C, Monticelli F, Yiu C. In vivo and in vitro permeability of one-step self-etch adhesives. J Dent Res2004;83:459-64.  Back to cited text no. 14
    
15.Hegde MN, Hegde P, Shetty SK. The influence of salivary contamination on the shear bond strength of two newer generation dentin bonding agents - An in vitro study. J Conserv Dent 2008;11:127-30.  Back to cited text no. 15
[PUBMED]  Medknow Journal  
16.Neelagiri K, Kundabala M, Shashi RA, Thomas MS, Parolia A. Effects of saliva contamination and decontamination procedures on shear bond strength of self-etch dentine bonding systems: An in vitro study. J Conserv Dent 2010;13:71-5.  Back to cited text no. 16
[PUBMED]  Medknow Journal  
17.Oonsombat C, Bishara SE, Ajlouni R. The effect of blood contamination on the shear bond strength of orthodontic brackets with the use of a new self-etch primer. Am J Orthod Dentofacial Orthop 2003;123:547-50  Back to cited text no. 17
    
18.YooHM, Oh TS, Pereira PN. Effect of saliva contamination on the microshear bond strength of one-step self-etching adhesive systems to dentin.Oper Dent2006;31:127-34.  Back to cited text no. 18
    
19.Hitmi L, Attal JP, Degrange M. Influence of the time-point of salivary contamination on dentin shear bond strength of 3 dentin adhesive systems.J Adhes Dent 1999;1:219-32.  Back to cited text no. 19
    
20.Finger WJ, Lee KS, Podszun W. Monomers with lowoxygeninhibition as enamel/ dentinadhesives. Dent Mater1996;12:256-61.  Back to cited text no. 20
    
21.Barakat MM, Powers JM. In vitro bond strength of cements to treated teeth. Aust Dent J. 1986;31:415-419.  Back to cited text no. 21
    

Top
Correspondence Address:
Madhusudhana Koppolu
Department of Conservative Dentistry and Endodontics, Narayana Dental College, Nellore - 524 003, Andhra Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0972-0707.97956

Rights and Permissions


    Figures

  [Figure 1]
 
 
    Tables

  [Table 1], [Table 2], [Table 3]

This article has been cited by
1 Effect of contamination and decontamination methods on the bond strength of adhesive systems to dentin: A systematic review
Rim Bourgi, Carlos Enrique Cuevas-Suarez, Walter Devoto, Ana Josefina Monjarás-Ávila, Paulo Monteiro, Khalil Kharma, Monika Lukomska-Szymanska, Louis Hardan
Journal of Esthetic and Restorative Dentistry. 2023;
[Pubmed] | [DOI]
2 The Influence of Saliva and Blood Contamination on Bonding Between Resin-modified Glass Ionomer Cements and Resin Composite
B Mar, M Ekambaram, KC Li, J Zwirner, ML Mei
Operative Dentistry. 2023; 48(2): 218
[Pubmed] | [DOI]
3 Influence of nonthermal argon plasma on the micro-shear bond strength between resin cement and translucent zirconia
Kimia Salimi, Faezeh Atri, Sara Valizadeh, Majid Sahebi, Safoura Ghodsi, Neshatafarin Manouchehri
Journal of Conservative Dentistry. 2023; 26(3): 281
[Pubmed] | [DOI]
4 Longevity of gold restorations in posterior teeth: A retrospective study up to 10-years
Iris Frasheri, Reinhard Hickel, Juergen Manhart, Christian Diegritz, Matthias Folwaczny, Christina Fotiadou
Journal of Dentistry. 2022; 124: 104235
[Pubmed] | [DOI]
5 The Effect of Dentin Contamination by Topical Anesthetics on Micro-Shear Bond Strength: An In Vitro Experiment
Nattawit Niyomsujarit, Pathomrat Uttamang, Meghna Burad, Nadaprapai Sipiyaruk, Kawin Sipiyaruk
International Journal of Environmental Research and Public Health. 2022; 19(24): 16567
[Pubmed] | [DOI]
6 Comparative evaluation of different surface treatments of the salivary contaminated dentin on the shear bond strength of self-etch adhesives: An in vitro study
Himanshi Tehlan, Ashima Garg
Journal of Conservative Dentistry. 2022; 25(4): 436
[Pubmed] | [DOI]
7 Use of rubber dam versus cotton roll isolation on composite resin restorations’ survival in primary molars: 2-year results from a non-inferiority clinical trial
Isabel C. Olegário, Bruna L. P. Moro, Tamara K. Tedesco, Raiza D. Freitas, Ana Laura Pássaro, Jonathan Rafael Garbim, Rodolfo Oliveira, Fausto M. Mendes, Annelry Costa Serra, Antonio Carlos Lopes Silva, Carolina de Picoli Acosta, Caroline Mariano Laux, Cíntia Saori Saihara, Haline Cunha Medeiros Maia, Isabel Cristina Olegário, Isabella Ronqui de Almeida, Jhandira Daibelis Yampa Vargas, José Carlos P. Imparato, Julia Gomes Freitas, Karina Haibara De Natal, Kim Rud Ekstrand, Laura Regina Antunes Pontes, Mariana Bifulco, Mariana Minatel Braga, Mariana Pinheiro Araújo, Mayume Amorim do Vale, Renata Marques Samuel, Rita Baronti, Simone Cesar, Tathiane Larissa Lenzi, Tatiane Fernandes Novaes, Thais Gimenez, Cacia Signori, Maximiliano Sérgio Cenci, Daniela Prócida Raggio
BMC Oral Health. 2022; 22(1)
[Pubmed] | [DOI]
8 Novel Use of Tranexamic Acid to Reduce Time Taken During Bracket Placement for Orthodontic Traction of Impacted Teeth: An Observational Study
Amit Mahajan, Ankit Patel, Neha Shukla, Nishita shah
Journal of Maxillofacial and Oral Surgery. 2022;
[Pubmed] | [DOI]
9 Influence of different contaminants and cleansing agents on bond strength and in situ degree of conversion of composite-adhesive interface
Emanuela Gaviolli, Elenusa Oltramari Vieira, Felipe Dornelles da Silva, Luiz Felipe Valandro, Sailer Santos dos Santos, Françoise Hélène van de Sande, Ataís Bacchi, Gabriel Kalil Rocha Pereira, Rodrigo Varella de Carvalho
International Journal of Adhesion and Adhesives. 2021; 110: 102932
[Pubmed] | [DOI]
10 effect of saliva contamination on the shear bond strength of a new self-etch adhesive system to dentin
munaga, s. and chitumalla, r. and kubigiri, s. and rawtiya, m. and khan, s. and sajjan, p.
journal of conservative dentistry. 2014; 17(1): 31-34
[Pubmed]
11 Effect of salivary contamination on the bond strength of total-etch and self-etch adhesive systems: An in vitro study
Justin, R.M. and Paranthaman, H. and Rajesh, A.G. and Varghese, R.P. and Ranganath, L.M.
Journal of Contemporary Dental Practice. 2012; 13(5): 655-660
[Pubmed]
12 Effect of Salivary Contamination on the Bond Strength of Total-etch and Self-etch Adhesive Systems: An in vitro Study
LM Ranganath, AG Rajesh, Robert M Justin, Hemalatha Paranthaman, Ranjith P Varghese
The Journal of Contemporary Dental Practice. 2012; 13(5): 655
[Pubmed] | [DOI]



 

Top
 
 
 
  Search
 
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Email Alert *
    Add to My List *
* Registration required (free)  
 


    Abstract
   Introduction
    Materials and Me...
   Results
   Discussion
   Conclusions
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed4645    
    Printed186    
    Emailed0    
    PDF Downloaded297    
    Comments [Add]    
    Cited by others 12    

Recommend this journal