An in vitro appraisal of properties of dental amalgam using commercially available and ayurvedically recycled mercury: Recycle and reuse


1 Department of Dentistry, Faculty of Dental Sciences, IMS, BHU, Varanasi, Uttar Pradesh, India
2 Department of Metallurgical Engineering, IIT, BHU, Varanasi, Uttar Pradesh, India
3 Department of Mechanical Engineering, IIT, BHU, Varanasi, Uttar Pradesh, India

Click here for correspondence address and email

Date of Submission18-Mar-2018
Date of Decision20-Jun-2018
Date of Acceptance03-Aug-2018
Date of Web Publication13-Nov-2018
 

   Abstract 

Introduction: With the introduction of tooth-colored restoration material, the usage of amalgam has reduced over years. However, results regarding toxicity and health concerns are conflicting. Based on the concept of recycle and reuse, we previously used an ayurvedic method for purification of excess mercury obtained from dental operatory. In the present study, we aimed to evaluate the properties of dental amalgam using commercially available and ayurvedically recycled mercury.
Materials and Methods: Samples were prepared for analysis of mean compressive strength, Vickers hardness number, and coefficient of friction dental amalgam using commercially available and ayurvedically recycled mercury. Further analysis was done using scanning electron microscopy. The data were presented on Microsoft Excel Spreadsheet 2013 and statistical analysis was done on IBM SPSS software (IBM Analytics) and OriginPro 8 software.
Results and Conclusion: No statistically significant difference was found in properties of dental amalgam prepared using commercially available and ayurvedically recycled mercury. Although not statistically significant, early compressive strength and hardness of amalgam using ayurvedically recycled mercury were comparatively higher, which may be attributed to residual amounts of silver, tin, and copper acting as nucleating agent for faster setting reaction.

Keywords: Amalgam; coefficient of friction; compressive strength; electron microscopy; Vickers hardness

How to cite this article:
Pandiar D, Baranwal HC, Chattopadhyay K, Kumar P. An in vitro appraisal of properties of dental amalgam using commercially available and ayurvedically recycled mercury: Recycle and reuse. J Conserv Dent 2018;21:651-6

How to cite this URL:
Pandiar D, Baranwal HC, Chattopadhyay K, Kumar P. An in vitro appraisal of properties of dental amalgam using commercially available and ayurvedically recycled mercury: Recycle and reuse. J Conserv Dent [serial online] 2018 [cited 2018 Dec 16];21:651-6. Available from: http://www.jcd.org.in/text.asp?2018/21/6/651/245239

   Introduction Top


Dental amalgam has served the dental profession well for more than 150 years. It has been stated that in terms of economics and longevity, there is no better alternative to amalgam.[1] By virtue of its high compressive strength, it is mainly used for restoration of posterior teeth. Although its usage has decreased in private clinical practice, it is still used in dental schools and is also a material of choice when the patient cannot afford costly dental treatment. It has recently been found that in Canadian population, the mean urinary mercury concentrations were significantly lower than the values considered to pose any risks for health.[2] Similarly, no systemic genotoxicity was observed in an Indian cohort due to the components of amalgam restorations released during its placement and chronic use.[3] Further, no significant link has been found between the usage of mercury with diseases such as multiple sclerosis and Alzheimer's disease.[4] The American Dental Association has endorsed amalgam as being safe for pregnant women.

The major limitations are its poor esthetics, no bonding with tooth structures, and disposal of excess mercury and amalgam waste. In a preliminary attempt, we used samanaya shodhana (purification) process from ayurvedic text (Rasa Shastra) for management of excess mercury obtained from dental clinics. With the use of lime powder, fresh garlic cloves, and rock salt, the excess mercury collected from dental operatory was purified. The effectiveness of purification was tested by inductively coupled plasma mass spectrometry (ICP-MS), and we found that amount of silver, tin, and copper markedly reduced after samanya shodhana.[5]

In the present paper, we attempted to compare the properties of amalgam using commercially available and ayurvedically recycled mercury to testify if recycled mercury yields dental amalgam at par in properties with dental amalgam using commercially available mercury. Furthermore, the microstructure was analyzed using scanning electron microscope.


   Materials and Methods Top


The study was conducted in the Conservative Dentistry and Endodontics unit in collaboration with Departments of Metallurgical and Mechanical Engineering over a period of 2 years. Prior approval was obtained from the Departmental Research Committee.

Estimation of compressive strength, Vickers hardness number, and tribology

To create the samples for estimating compressive strength, we used cylindrical plastic molds with 6 mm internal diameter and 8 mm height. Triple distilled mercury (Deepak Enterprises, Mulund, Mumbai, Maharashtra, India) was triturated with zinc-free DPI Alloy (The Bombay Burmah Trading Corporation Ltd., Mumbai, Maharashtra, India) to prepare a homogenous mass. This amalgamated mass was squeezed in chamois leather and condensed into the mold using a stainless-steel instrument with the diameter less than the internal diameter of the mold. Fifteen samples were prepared for measuring the samples' compression strength of the control specimen (Group 1). Similarly, 15 specimens were prepared using mercury recycled by samanya shodhana (Group 2). These samples were stored in an incubator maintained at 37°C ± 1°C until used. Three samples were used from each group for estimation of compressive strength 1 h after the amalgamation. The subsequent measurements were taken on days 1, 4, 7, and 10. The compressive strength was measured by Instron Universal testing instrument (Model 4206; INSTRON Ltd., Buckinghamshire, England) which had a computer system.

For measurement of Vickers hardness (HV), disc-shaped specimen was prepared with a diameter of 10 mm using both commercially available mercury and recycled mercury. One end of each sample was first manually ground by the sandpaper No. 120, followed by 180, 220, 400, and 800. The final polishing was done using pumice slurry. All the samples were stored in an incubator at the temperature of 37°C ± 1°C until used on days 1, 4, 7, and 10. On each day, three readings were obtained for both the groups and mean was calculated. The discs were polished every time before obtaining the readings. The measurement of the HV was done using Auto Turret Digital Micro HV Tester (Vertex, Mumbai, India). Here, a square-based pyramid is pressed on the surface of polished amalgam discs. The impression obtained was square shaped. HV is computed as load divided by the projected area of indentation. The length of the diagonals of the indentation was measured and averaged.

For checking the friction and wear behavior, occlusal surface of crowns of extracted molar was flattened using diamond cutting tips and crowns of teeth were embedded in plaster of square brick shape of dimension 1.5 cm × 1.5 cm × 0.3 cm. Test samples were made using both commercially available and recycled mercury in cylindrical shape of dimensions 12 mm height and 6 mm diameter. The samples were stored in an incubator at 37°C ± 1°C until used on day 7. Reciprocating sliding wear and friction monitor (Magnum Engineers, Bengaluru, Karnataka, India) were used and coefficient of friction and total weight loss of each sample was assessed.

Scanning electron microscopic analysis of dental amalgam using commercial available mercury and ayurvedically recycled mercury

Ten maxillary first premolars (extracted for orthodontic purpose) were used for Scanning electron microscopic (SEM) study; 5 teeth were used as cases and remaining 5 were used as controls. Conservative Class I preparation was made. Five teeth were filled with amalgam using commercially available Hg and rest five were restored with amalgam using recycled mercury. All the teeth were cut into two equal halves in buccolingual direction. Only one half of each tooth was used for analysis. Assessments were made using photomicrograph picture taken on the scanning electron microscope (EVO 18 research SEM, Carl Zeiss, Germany). Parameters used in SEM study were marginal adaptation of amalgam with tooth and voids within the restoration. The scoring was done as follows:

  1. Marginal adaptation


    • Good (Score 3): All three walls closely adapted (pulpal, buccal, and lingual)
    • Intermediate (Score 2): Two walls adapted closely
    • Poor (Score 1): Only one wall shows close adaptation.


  2. Voids within the restoration


    • Score 1: 0–2 voids per 3 1000× fields
    • Score 2: 2–4 voids per 3 1000× fields
    • Score 3: >4 voids per 3 1000× fields.


The data were presented on Microsoft Excel SpreadSheet 2013 and statistical analysis was done on IBM SPSS software (IBM Analytics, Armonk, New York, U.S.). Compressive strength and HV were compared between two groups using Levene's test for equality of variances and t-test for equality of means. Graphing and data analysis for tribology of both the groups was analyzed using OriginPro 8 software (OriginLab Corporation, Northampton, Massachusetts, USA). Comparison of microstructure was done using Pearson's Chi-square test.


   Results Top


Compressive strength

Mean compressive strength (MCS) for Group 1 was estimated after 1 h and on days 1, 4, 7, and 10 and compared to the values obtained for Group 2 [Figure 1]a. MCS in Group 1 after 1 h, and on day 1, 4, 7, and 10 were 59.39, 301.47, 300.47, 300.20, and 299.17, respectively (in MPa). For Group 2, the values of MCS were 63.38 (after 1 h), 301.90 (on day 1), 293.13 (on day 4), 301.33 (on day 7), and 297.70 (on day 10). [Table 1] shows the results most relevant to independent sample t-test providing two sets of information: (1) Levene's Test for Equality of Variance and (2) “t”-test for equality of means. No statistical significant difference was seen in MCS between the two groups after 24 h and on days 1, 4, 7, and 10.
Figure 1: (a) Graph showing comparison of mean compressive strength (in MPa) of Group 1 and Group 2 after 1 h, after 24 h, and on days 4th, 7th, and 10th; (b) Graph showing comparison of mean of Vickers hardness number of Group 1 and Group 2 after 24 h and on days 4th, 7th, and 10th; (c) Example graphs of coefficient of friction during the single test with running average: Couple of amalgam material using recycled mercury and enamel; (d) Example graphs of coefficient of friction during the single test with running average: Couple of amalgam material using commercially available mercury and enamel

Click here to view
Table 1: Comparison of mean compressive strength between the study groups on days 0, 1, 4, 7, and 10

Click here to view


Vickers hardness number

Mean HV (MHV) for Group 1 was estimated on days 1, 4, 7, and 10 and values were compared with Group 2 [Figure 1]b. MHV in Group 1 on day 1, 4, 7, and 10 was 56, 57, 71, and 73, respectively. For Group 2, the values of MHV were 60 (on day 1), 70 (on day 4), 72 (on day 7), and 85 (on day 10).

[Table 2] shows the results most relevant to independent sample t-test for comparison of HV between the two groups. The table provides two sets of information: (1) Levene's Test for Equality of Variance and (2) “t”-test for equality of means. Although the values recorded for Group 2 was comparatively higher than Group 1, no statistical difference in MHV between the two test groups on days 1, 7, and 10 (P > 0.05). However, it was interesting to note that on day 4 HV of Group 2 was significantly higher than HV of Group 1 (P < 0.05; df 4).
Table 2: Comparison of Vickers hardness between the study groups on days 1, 4, 7, and 10

Click here to view


Friction and wear behavior

It was found that Group 1 showed a comparatively higher weight loss and lower coefficient of friction as compared to Group 2. Detailed values are shown in [Table 3] and [Figure 1]c and [Figure 1]d.
Table 3: Weight loss and coefficient of friction of Groups 1 and 2

Click here to view


Scanning electron microscopic analysis of dental amalgam using commercial available mercury (Group 1) and ayurvedically recycled mercury (Group 2)

[Figure 2] shows scanning electron microscopic photomicrographs from representative areas of acceptable restorations and void & gaps in the restorations. No statistically significant difference was seen in marginal adaptation score and number of voids in restoration between two study groups (P > 0.05) [Table 4] and [Table 5].
Figure 2: Scanning electron microscopic photomicrograph showing acceptable restoration (a and c); (b) Void within the restoration; and (d) Gap between tooth and restoration

Click here to view
Table 4: Comparison of marginal adaptation between the study groups

Click here to view
Table 5: Comparison between the study groups for voids within the restoration

Click here to view


Compressive strength after 1 year

Although it was not initially intended, we checked compressive strength of dental amalgam using commercially available mercury and ayurvedically recycled mercury 1 year after initial values. Samples were prepared as mentioned above and values were recorded after 1 h and 24 h since maximum gain in compressive strength is seen during first 24 h. After 1 h, MCS in Group 1 was 60.40 and it rose to 307.13 after 24 h. For Group 2, the values of MCS were 61.65 (after 1 h) and 309.21 (on day 1). [Table 6] shows the results most relevant to independent sample t-test. It was observed that after 1 h and 24 h, there was no statistical difference in compressive strength between the two groups (P > 0.05).
Table 6: Comparison of mean compressive strength between the study groups on days 0 and 1 (values were obtained 1 year after initial values)

Click here to view



   Discussion Top


Mercury release from amalgam restoration and consequent toxicity has been a matter of concern. Although it was found that urine mercury level in a study group was too low to pose health risks, Zwicker et al. were more in favor of alternative restorative materials. The conclusion was deducted on the basis of results that removal of amalgam fillings reduced the self-reported symptom deterioration and increased the possibility of symptom improvement in comparison to people who retained their amalgam fillings.[6] In contrast, Nicolae et al. opined that mean urinary mercury concentrations in Canadian population are significantly lower than the values considered to pose any risks for health.[3] Similarly, Priya et al. observed no systemic genotoxicity due to the components of amalgam restorations.[2] No differences in neurobehavioral assessments or nerve conduction velocity have been reported among children with amalgam restoration when compared to children with composite resin restoration.[7] Further adding to the information, Miriam Varkey et al. concluded that environmental factors such as fishes collectively overpower the exposure levels from amalgam restorations alone.[8] Thus, based on literature review, we could not find any solid background to ban amalgam restoration from dental profession. One major problem which we came across was disposal of excess mercury.

In a preliminary attempt to recycle and reuse the excess mercury, we used a novel procedure of Ayurveda, namely, samanaya shodhana and found that after purification the level of silver, tin, and copper was markedly reduced. Purified mercury showed a level of 119.5 ppm silver, 0.5324 ppm copper, and 0.3233 ppm tin. Amount of silver, copper, and tin in commercially available mercury, as depicted by ICP-MS, were 11.69, 1.1069, and 0.1045, respectively (in ppm).[5] In the present study, we compared the properties of dental amalgam using commercially available and ayurvedically recycled mercury to test whether recycled mercury be satisfactorily reused.

After 1 h, MCS obtained 59.39 MPa for commercially available mercury which was comparatively less as compared to MCS obtained from amalgam using recycled mercury (63.38 MPa), although there was no statistically significant difference between two groups. It was further observed that the maximum gain in compressive strength was seen after 24 h which is in accordance with the findings of Malhotra and Asgar and Duke et al. who stated that in high copper amalgam the greatest increase in strength is achieved in the period from 1 h to 24 h.[9],[10] Suchatlampong et al. in their study confirmed the aforementioned results and found a significant correlation between the ratio of early compressive strength and the diffraction intensity ratio for γ1 indicating an increase in early compressive strength is mainly dependent on the formation of γ1. This gain in early compressive strength is important from clinical point for assessing resistance of amalgam restoration to early fractures.[11]

The values of MCS showed no significant change on 4th, 7th, and 10th day. Rajih et al. showed improvement in wear resistance, hardness, and compressive strength by the addition of oxides of zinc and titanium.[12] Many other similar attempts have been made for the improvement of properties of dental amalgam. Although it was not initially intended, we assessed the compressive strength after 1 year to evaluate whether the purified mercury has a prolonged shelf life or not. We found that even after 1 year, there was no statistical difference in compressive strength between the two groups after 1 h and 24 h (P > 0.05). Furthermore, the obtained values after 1 year were close to the initial values.

With regard to HV number, the hardness increased to a maximum of 85 using recycled mercury which was higher as compared to a value of 73 for control. However, the results showed no significant difference except on day 4 where it was noticed that the hardness using recycled mercury was significantly more than controls. Our values were much lower than the values obtained by Rajih et al. and Razavi et al. in their study.[12],[13] This may be due to the fact that there was difference in the alloy used yielding varied results.

Despite the fact that there was no statistical difference in compressive strength and HV number between two study groups, the values were comparatively higher using ayurvedically recycled mercury, and this may be attributed to the fact that residual silver, copper, and tin may act as nucleating centers resulting in faster setting reaction and early gain in compressive strength and hardness.

In an early study, Tillitson et al. detected the coefficient of friction of dental amalgam with respect to dry bovine enamel and found it to be in a range of 0.180–0.22.[14] The coefficient of friction using commercially available mercury was 0.086 ± 0.009 which was found to be lower than the value of amalgam using recycled mercury (0.144 ± 0.15), but both the values were close to the range provided by Tillitson et al. They also found that the relative abrasive wear of materials follow the order of the hardness of the materials. Although not statistically significant, we found that HV for Group 2 was higher than Group 1 and this corresponded with their values of coefficient of friction and amount of weight loss during estimation of friction coefficient. It was stated that a pair of materials exhibiting a higher value of coefficient of friction might offer greater frictional resistance under identical conditions, hence should be the material of choice for restoring the buccal or guiding plane surfaces of a tooth, where indicated.[15] Thus, dental amalgam restorations using shodhit mercury with higher MCS, HV, and coefficient of friction and lesser weight loss might serve even better than amalgam restorations triturated with commercially available mercury.

We further processed samples for scanning electron microscopy for evaluation of marginal integrity and voids within the restoration. Restorations with recycled mercury matched commercially available mercury as no statistical significant difference was found between the two groups.


   Conclusion Top


Based on the concept of recycle and reuse, we thus conclude that excess mercury from dental operatory can be satisfactorily recycled by samanaya shodhana as the process greatly reduce the amount of silver tin and copper as depicted by ICP-MS. After purification, the residual Ag, Sn, and Cu may act nucleating centers causing faster setting reaction and an early gain in MCS and hardness. There was no difference in the properties of the amalgam prepared by commercially available and ayurvedically recycled mercury. Thus, further research is warranted to check if samanaya shodhana is feasible on a larger scale and in vivo use of ayurvedically recycled mercury.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
   References Top

1.
Berry TG, Summitt JB, Chung AK, Osborne JW. Amalgam at the new millennium. J Am Dent Assoc 1998;129:1547-56.  Back to cited text no. 1
    
2.
Priya EL, Ranganathan K, Rao UD, Joshua E, Mathew DG, Wilson K, et al. A study of sister chromatid exchange in patients with dental amalgam restorations. Indian J Dent Res 2014;25:772-6.  Back to cited text no. 2
[PUBMED]  [Full text]  
3.
Nicolae A, Ames H, Quiñonez C. Dental amalgam and urinary mercury concentrations: A descriptive study. BMC Oral Health 2013;13:44.  Back to cited text no. 3
    
4.
Shenoy A. Is it the end of the road for dental amalgam? A critical review. J Conserv Dent 2008;11:99-107.  Back to cited text no. 4
[PUBMED]  [Full text]  
5.
Pandiar D, Baranwal HC, Chattopadhyay K, Choudhary AK, Ganesan V, Sonkar PK. Utilization of Samanya Shodhana in the purification of excess mercury obtained from dental operatory – A preliminary study. Int J Ayurveda Pharm Res 2018;6:8-13.  Back to cited text no. 5
    
6.
Zwicker JD, Dutton DJ, Emery JC. Longitudinal analysis of the association between removal of dental amalgam, urine mercury and 14 self-reported health symptoms. Environ Health 2014;13:95.  Back to cited text no. 6
    
7.
DeRouen TA, Martin MD, Leroux BG, Townes BD, Woods JS, Leitão J, et al. Neurobehavioral effects of dental amalgam in children: A randomized clinical trial. JAMA 2006;295:1784-92.  Back to cited text no. 7
    
8.
Miriam Varkey I, Shetty R, Hegde A. Mercury exposure levels in children with dental amalgam fillings. Int J Clin Pediatr Dent 2014;7:180-5.  Back to cited text no. 8
    
9.
Malhotra ML, Asgar K. Physical properties of dental silver-tin amalgams with high and low copper contents. J Am Dent Assoc 1978;96:444-50.  Back to cited text no. 9
    
10.
Duke ES, Cochran MA, Moore BK, Clark HE. Laboratory profiles of 30 high copper amalgam alloys. J Am Dent Assoc 1982;105:636-40.  Back to cited text no. 10
    
11.
Suchatlampong C, Goto S, Ogura H. Early compressive strength and phase-formation of dental amalgam. Dent Mater J 1995;14:143-51.  Back to cited text no. 11
    
12.
Rajih AK, Al-Sultani KF, Al-Kinani MA. Mechanical properties improvement of dental amalgam using TiO2 and ZnO. Life Sci J 2015;12:86-90.  Back to cited text no. 12
    
13.
Razavi SH, Mirdamadi S, Hormozi M. Investigating the physical and mechanical properties of high-copper and silver dental-filling amalgam alloys. Iran J Mater Sci Eng Winter 2011;8:40-7.  Back to cited text no. 13
    
14.
Tillitson EW, Craig RG, Peyton FA. Friction and wear of restorative dental materials. J Dent Res 1971;50:149-54.  Back to cited text no. 14
    
15.
Ali M. The measurement of co-efficient of friction between cast Co-Cr alloy and guiding plane materials – A pilot study. Pak Oral Dent J 2002;22:63-6.  Back to cited text no. 15
    

Top
Correspondence Address:
Dr. Deepak Pandiar
Department of Dentistry, Faculty of Dental Sciences, IMS, BHU, Varanasi, Uttar Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/JCD.JCD_114_18

Rights and Permissions


    Figures

  [Figure 1], [Figure 2]
 
 
    Tables

  [Table 1], [Table 2], [Table 3], [Table 4], [Table 5], [Table 6]



 

Top
 
 
 
  Search
 
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Email Alert *
    Add to My List *
* Registration required (free)  
 


    Abstract
   Introduction
    Materials and Me...
   Results
   Discussion
   Conclusion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed101    
    Printed1    
    Emailed0    
    PDF Downloaded41    
    Comments [Add]    

Recommend this journal