Journal of Conservative Dentistry
Home About us Editorial Board Instructions Submission Subscribe Advertise Contact e-Alerts Login 
Users Online: 914
Print this page  Email this page Bookmark this page Small font sizeDefault font sizeIncrease font size
ORIGINAL ARTICLE
Year : 2018  |  Volume : 21  |  Issue : 6  |  Page : 607-612

Reliability and accuracy of linear measurements in cone-beam computed tomography using different software programs and voxel sizes


1 Department of Dentistry, State University of Maringá, Maringá, PR, Brazil
2 Department of Dentistry, Federal University of Sergipe, Aracajú, SE, Brazil

Correspondence Address:
Dr. Elen de Souza Tolentino
Avenida Mandacaru, 1550, Maringa - PR
Brazil
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/JCD.JCD_314_18

Rights and Permissions

Objectives: The aim of this study is to evaluate the accuracy of linear measurements on cone-beam computed tomography (CBCT) images using three software programs and different voxel sizes. Methods: Ten human mandibles with 25 silica markers were scanned for 0.250-, 0.300-, and 0.400-mm voxels in the i-CAT New Generation (Imaging Sciences International, Hatfield, PA, USA). Thirty-five linear measurements were carried out by two examiners two times on the multiplanar reconstructions in the following software programs: XoranCat version 3.1.62 (Xoran Technologies, Ann Arbor, MI, USA), RadiAnt DICOM 2.2.9 Viewer (Medixant, Poznan- Poland) and InVesalius 3.0.0 (Centro de Tecnologia da Informação Renato Archer, Campinas, SP, Brazil). The physical measurements were made by another observer two times using a digital caliper on the macerated mandibles. ANOVA test was used to compare voxels and software programs. Pearson correlation and the Bland–atman tests were used to compare physical and virtual measurements and to evaluate the accuracy of the software programs, respectively (P < 0.05). Results: There was no statistically significant difference when the measurements were compared in acquisitions with different voxel sizes analyzed in the three software programs. There was also no difference when the measurements were compared between the software programs and the digital caliper. Excellent intra- and inter-observer reliability for the markers, physical measurements, and multiplanar reconstructions were found. Conclusion: Linear measurements in the XoranCat, Radiant, and InVesalius software programs are reliable and accurate compared with physical measurements. The different acquisition protocols using different voxel sizes did not influence the accuracy of linear measurements in CBCT images.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed95    
    Printed2    
    Emailed0    
    PDF Downloaded17    
    Comments [Add]    

Recommend this journal