Journal of Conservative Dentistry
Home About us Editorial Board Instructions Submission Subscribe Advertise Contact e-Alerts Login 
Users Online: 1463
Print this page  Email this page Bookmark this page Small font sizeDefault font sizeIncrease font size
ORIGINAL ARTICLE
Year : 2016  |  Volume : 19  |  Issue : 2  |  Page : 189-193

An in vivo assessment of the influence of needle gauges on endodontic irrigation flow rate


Dr M.G.R. Educational and Research Institute University, Thai Moogambigai Dental College and Hospital, Chennai, Tamil Nadu, India

Correspondence Address:
Velayutham Gopikrishna
Thai Moogambigai Dental College and Hospital, Golden George Nagar, Chennai - 600 107, Tamil Nadu
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0972-0707.178708

Rights and Permissions

Aim: The aim of this clinical study was to assess the influence of irrigation needle gauge on endodontic irrigation flow rates. Settings and Design: In vivo assessment. Materials and Methods: Five specialist endodontists performed intracanal irrigation procedures on 50 mesiobuccal canal of mandibular first molars using three different irrigation needle gauges. Data of time taken for irrigation was recorded by an irrigation testing system and analyzed using independent sample "T" test and one-way analysis of variance (ANOVA) test. The level of significance was set at P < 0.05. Statistical Analysis Used: The following tests were used for the statistical analysis: Independent sample "T" test, one-way ANOVA test, and post hoc multiple comparison was carried out using Tukey's honest significant difference (HSD) test using Statistical Package for the Social Sciences (SPSS) version 16 for Windows. Results: The average flow rate of 26 gauge was 0.27 mLs−1 , of 27 gauge was 0.19 mLs−1 , and of 30 gauge was 0.09 mls−1 . There was statistical significance among the gauges (P < 0.001). 26 gauge had highest flow rate when compared with other groups followed by 27 gauge and 30 gauge respectively. The operator variability for flow rate of three endodontic irrigation needle gauges (26 gauge, 27 gauge, and 30 gauge) was found to be not significant. Conclusions: Needle gauge has significant influence on endodontic irrigation flow rate.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2236    
    Printed28    
    Emailed0    
    PDF Downloaded358    
    Comments [Add]    

Recommend this journal