Three-dimensional evaluation of surface roughness of resin composites after finishing and polishing


1 Department of Cons and Endo, M.R. Ambedkar Dental College and Hospital, Bangalore, Karnataka, India
2 Department of Cons and Endo Cos and Endo, PMS Dental College, Golden Hills, Thiruvananthapuram, Kerala, India

Click here for correspondence address and email

Date of Submission27-Sep-2015
Date of Decision02-Nov-2015
Date of Acceptance23-Dec-2015
Date of Web Publication5-Jan-2016
 

   Abstract 

Aim: This study aims to investigate the effects of finishing and polishing procedures on four novel resin composites using three-dimensional optical profilometer.
Materials and Methods: Four composites classified according to their filler size, were selected: Filtek Z350 XT/Nanofill (3M™ ESPE™), Esthet-X HD/Hybrid (Dentsply Caulk), Te Econom/Microfill (Ivoclar Vivadent ® ), Tetric EvoCeram ® /Nanohybrid (Ivoclar Vivadent ® ). Composite specimens were made in Plexiglass mold and polished with Soflex (3M ESPE), Enhance + Pogo (Dentsply Caulk). Both the systems were used according to the manufacturers' instructions, and the polished surfaces were assessed with an optical profilometer.
Statistical Analysis Used: Kruskal-Wallis test and further pairwise comparison were performed by Mann-Whitney test.
Results: The smoothest surfaces for all the resin composites tested were obtained from the Mylar strip; statistically significant differences were observed among them (P = 0.001). The order of composites was ranked from the lowest to highest surface roughness; Filtek Z350 XT < Te Econom < Tetric EvoCeram < Esthet XHD. Pairwise multiple comparison with Mann-Whitney test showed Filtek Z350 to have the smoothest surface and the least with Teric EvoCeram. Among the polishing systems, Soflex showed the smoothest surface and was significantly different from Pogo (P = 0.046).
Conclusions: The effectiveness of the polishing systems seems to be dependent on the material used, treatment modality and also on the filler particle size.

Keywords: Composite; finishing; optical profilometer surface roughness; polishing

How to cite this article:
Nair VS, Sainudeen S, Padmanabhan P, Vijayashankar L V, Sujathan U, Pillai R. Three-dimensional evaluation of surface roughness of resin composites after finishing and polishing. J Conserv Dent 2016;19:91-5

How to cite this URL:
Nair VS, Sainudeen S, Padmanabhan P, Vijayashankar L V, Sujathan U, Pillai R. Three-dimensional evaluation of surface roughness of resin composites after finishing and polishing. J Conserv Dent [serial online] 2016 [cited 2019 Sep 19];19:91-5. Available from: http://www.jcd.org.in/text.asp?2016/19/1/91/173208

   Introduction Top


The proper finishing and polishing of dental restoratives are significant to promote a plaque-free environment and to enhance the esthetics and longevity of restoration. Weitman and Eames stated that plaque accumulation occurs on composite samples with a surface roughness of 0.7-1.44 um. [1] Early studies have shown that curing composite against a matrix strip will produce the smoothest surface. [2],[3] Unfortunately, in the clinical environment such a finish cannot be obtained, further some degree of finishing and polishing of restorations is usually necessary.

With the advancement of technology and material science, there is a drastic development of restorative composite resins and the finishing and polishing systems. The composite resins are generally classified according to the size, content, and filler type. The newer classification includes the nanoparticles and a mixture of particle sizes known as a hybrid, microhybrid, or minifill. [4],[5],[6] Studies have shown that filler size and shape can affect the surface roughness of composite resins. [7]

This study determined how the matrix and filler compositions of restorative materials influenced the ease with which they could be polished using the two polishing systems: Soflex (3M ESPE) and Enhance + Pogo (Dentsply caulk). Several authors have studied the evaluation of surface roughness of composites using mechanical profilometry. In this study, optical profilometer has been used for evaluation.

Optimal profilometer is a three-dimensional analysis method that provides both qualitative and quantitative representation, unlike with mechanical profilometer; here, the measuring device is optical beam. This device works on Descartes' law, i.e., a plane wave falling on a plane surface that is not totally absorbent undergoes reflection and propagates as a plane wave in the direction given. The apparatus works by measuring the distance between an internal reference and point of the surface. [8]


   Materials and Methods Top


For this study, four composites and two finishing and polishing systems were studied: The resin composites evaluated were a Nanofill composite (Filtek Z350), Nanohybrid (Tetric EvoCeram), Hybrid (Esthet XHD), and Microfill (Te Econom). The finishing and polishing systems used were Enhance and Pogo kit (Dentsply Caulk) and Soflex kit (3M ESPE).

The study was conducted in the Department of Conservative Dentistry and Endodontics, Yenepoya Dental College Mangalore, India and Tata institute, Bangalore, India.

The methodology used in this study is described under the following subheadings:

  1. Preparation of specimens
  2. Polishing of specimens
  3. Surface roughness measurement
  4. Statistical analysis.


Preparation of specimen

Using a Plexiglass mold (8 mm × 2 mm), disc specimens were prepared. For each resin composite, 45 discs were fabricated and a total of 180 discs were obtained. Fifteen specimens per resin composite received no finishing treatment after being cured under Mylar strips and served as a control group. The resin composites were placed using a plastic instrument and covered with Mylar strip. A glass slide of 1-2 mm thick was placed over the strip before curing with light activated source to flatten the surfaces. The samples were then cured for 60 s through Mylar strip and glass slide. Output of light was checked using radiometer (so as to be in excess of 500w/cm 2 ). The curing unit was moved on both sides of the specimen for an additional 20 s after removing the strips and glasses. The cured samples were then stored in distilled water at 370°C for 24 h prior to finishing procedures. After storage, the Mylar created surfaces were evaluated with a profilometer on a flat plan to obtain average surface roughness and surface profile tracings that would serve as a baseline for the polishing system.

Polishing of specimens

For the first group, Sof-Lex™ 3M pop on discs at medium, fine, and superfine grits were used for 30 s each on the composite samples. After each step of polishing, all specimens were thoroughly rinsed with water and air-dried before the next step until final polishing. The second group was polished with Enhance discs followed by Pogo Dentsply discs. Each was applied for 30 s. For Pogo, first application was done with light intermittent pressure then with decreased pressure to increase the surface luster. The polished resin composite discs were washed, allowed to dry, and kept in distilled water at 37°C for 24 h before measuring average surface roughness (Ra).

Surface roughness measurement

The mean surface roughness of specimens was measured with an optical profilometer. The specimens were scanned at higher resolution with optical beam. The optical profilometer shows the three-dimensional topography of the specimens, allowing the materials to be classified according to the aspect of their surfaces.


   Results Top


The mean values and standard deviations of surface roughness for each resin composite are given in [Table 1], [Table 2], [Table 3], [Table 4], [Table 5]. The Kruskal-Wallis test shows significant surface roughness among the four resin composites and two polishing systems (P = 0.001). The smoothest surfaces for all the resin composites tested were obtained against the Mylar strip; statistically significant differences were observed among them (P = 0.001). The order of composites ranked from the lowest to highest surface roughness was Filtek Z350 < Te Econom < Tetric EvoCeram < Esthet XHD.
Table 1: Kruskal-Wallis test value for control


Click here to view
Table 2: Kruskal-Wallis test value for Group 1


Click here to view
Table 3: Kruskal-Wallis test value for Group 2


Click here to view
Table 4: Multiple comparison test in-between composite resins


Click here to view
Table 5: Multiple test comparisons in-between polishing system dependent variable: Roughness Bonferroni


Click here to view


Pairwise multiple comparison with Mann-Whitney test showed Filtek Z350 to have the smoothest surface and then Te Econom, but showed to be statistically different (P = 0.046). The least smooth surface occurred for Teric EvoCeram, which was not statistically different from Esthet X HD.

Among the polishing systems, Soflex showed the smoothest surface and was significantly different from Pogo (P = 0.046). Soflex exhibited the smoothest surface for Te Econom and roughest surface for Esthet XHD. Pogo exhibited the smoothest surface for Z350 and Te Econom and roughest surface for Tetric EvoCeram.

The three-dimensional profiles obtained by the optical method enabled a first appreciation of the surface states of each composite as shown in [Figure 1], [Figure 2], [Figure 3]. Rougher appearance is noticeable for Tetric EvoCeram and Esthet X HD. Soflex exhibited the smoothest finish for nanofill and microfill.
Figure 1: Control group (a) Filtek Z350 (b) Te Econom (c) Esthet XHD (d) Tetric EvoCeram


Click here to view
Figure 2: Soflex (a) Filtek Z350 (b) Te Econom (c) Esthet XHD (d) Tetric EvoCeram


Click here to view
Figure 3: Pogo (a) Filtek Z350 (b) Te Econom (c) Esthet XHD (d) Tetric EvoCeram


Click here to view



   Discussion Top


The smoothest surface was achieved when sample was polymerized with Mylar strip; on the other hand, as certain authors have shown, the surface layer rich in resin has to be eliminated. However, some functional adjustment is necessary on almost all clinical restorations. The presence of surface irregularities arising from poor finishing/polishing techniques and/or instruments can affect the surface quality of composites causing plaque accumulation, [9] staining, physical properties, [10] and recurrent decay, thus affecting the clinical performance of the restoration. The increase in surface roughness of resin composites cause patients discomfort in terms of tactile perception, [11] esthetic appearance, [12] and stain resistance. [13] A clinical trial has shown that a mean roughness of 0.3 μm could be easily detected by the patients by the tip of the tongue. [11]

It is clinically important to determine the finishing technique that results in the smoothest surface with the minimum time and instruments. For years, specially designed diamonds with very fine abrasive particle size and white Arkansas stone have been used to polish resin composite restorations. However, the use of diamond burs is limited to initial contouring because of their ability to remove equal amounts of adjacent enamel (Quiroz and Lentz 1986). Later, most of the emphasis was placed on the application of progressively finer grits of abrasives; the efficiency of abrasive systems is related to flexibility of the backing material, hardness of the abrasive, and how the instruments are used. [14] The abrasive particles must be relatively harder than the filler materials for the composite finishing to be effective, if not, the polishing agent will remove only the soft resin matrix leaving behind the filler particles protruding from the resin surface. [15] Various motions may be equally critical to the development of optimal surface smoothness. A rotary motion, a planar motion, and a reciprocating motion can be employed to polish the surface of resin composite. In this study, all the systems were tested using planar motion.

The size of filler particles has been used as an important parameter to characterize the restorative material for the purpose of clinical applications. Studies have shown that composites containing microfillers and nanofillers are more efficiently polished than hybrid resins. In this current study, the filler size ranged from 0.2 to 1.4 μm, and a clear relationship between filler size and composite surface roughness was observed.

In the present study, Filtek Z350XT and Te Econom showed lesser roughness compared to other resin composites, with a statistical difference of P = 0.046. The order of surface roughness ranked according to composite was Filtek Z350 < Econom < Tetric EvoCeram < Esthet XHD. The nanofill composite showed similar roughness as the microfill was not unexpected, as the nanofill composite evaluated in this study contains only particles of size below 100 nm, which is similar to the microfill composite.

In Filtek Z350, there is a combination of a nonagglomerated/nonaggregated (20 nm nanosilica filler) and loosely bound agglomerated zirconia/silica nanocluster with the particle size of 5-20 nm fillers and a cluster particle size of 0.6-1.4 μ. Since this composite presents nanofillers, in this study, Filtek Supreme Plus presented a lower surface roughness than other materials after polishing. This is not in accordance with Berger et al. who reported that Filtek Supreme did not present a lower surface roughness than other microfill and hybrid composites. [16] The microfill composite (Te Econom) presents an average particle size of 0.02-0.04 μ and exhibited lower or similar surface roughness to the nanofilled composite.

The Esthet-X composite is considered to have a microhybrid and minifill filler composition and contains inorganic (bariumalumino fluoroborosilicate glass (ranging from 0.02 to 2.5 μ) with nanosized silicon dioxide particles (range 10-20 nm). The size of the filler particles may be responsible for the differences in surface roughness between Esthet and Tetric EvoCeram when polished with Pogo and Soflex. Tetric EvoCeram showed a considerably higher reduction in surface roughness after having being polished with Soflex rather than after having been polished with Pogo. This may be due to the fact that the effectiveness of the polishing systems was material-dependent.

Most of the studies have shown that flexible aluminum oxide discs are the finest instruments for providing low surface roughness on composites. [17],[18],[19] This study showed lower performance regarding surface roughness when finished and polished with Soflex when compared to Pogo. Studies have shown that the flexible aluminum oxide discs produce the smoothest surface due to their capability to cut the filler particle and matrix equally. Both aluminum oxide discs and diamond discs affected the surface roughness of all microhybrid and nanohybrid resin composites. The various filler particle sizes in both the microhybrid and nanohybrid resin composites exposed to the surface after polishing could explain this result.

In this study, nanofill and microfill composites showed almost similar results when polished with Soflex and Pogo. Pogo showed greater surface roughness for nanohybrid composite (Tetric EvoCeram). Soflex showed increased surface roughness for hybrid composite (Esthet XHD).

Pogo system requires polishing at two different loads; therefore, interindividual differences in relation to manual application and polishing could have greater effects on results than is the case with Soflex.

In accordance with the current results, Watanabe et al. have showed that surface finish obtained using multistep systems (Soflex) was superior than two-step systems (Pogo). [20]

Surface profilometers have been used for years to measure surface roughness in in vitro investigations. Compared with optical profilometry, mechanical profilometry only gives a two-dimensional representation of the surface, which provides only little information. Here in this study, we have used optical profilometer to measure the surface roughness. The advantage of optical profilometer over mechanical is it uses beam of light to detect the tiny variations. The other advantage is it gives a quantitative aspect through the calculation of Ra and Rt. Another important advantage is that same specimens can be reused and could be reobserved after successive time intervals. [8]


   Conclusion Top


Nanoparticle and microfill composites were significantly smoother when compared with microhybrid and nanohybrid. The effect of finishing and polishing systems on the surface roughness of composites was material-dependent. Soflex polishers were more efficient than Pogo. Soflex showed better results in nanoparticle and microfill composites.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
   References Top

1.
Weitman RT, Eames WB. Plaque accumulation on composite surfaces after various finishing procedures. J Am Dent Assoc 1975;91:101-6.  Back to cited text no. 1
[PUBMED]    
2.
Bauer JG, Caputo AA. The surface of composite resin finished with instruments and matrices. J Prosthet Dent 1983;50:351-7.  Back to cited text no. 2
[PUBMED]    
3.
Heath JR, Wilson HJ. Surface roughness of restorations. Br Dent J 1976;140:131-7.  Back to cited text no. 3
[PUBMED]    
4.
Da Costa J, Ferracane J, Paravina RD, Mazur RF, Roeder L. The effect of different polishing systems on surface roughness and gloss of various resin composites. J Esthet Restor Dent 2007;19:214-24.  Back to cited text no. 4
    
5.
Jung M, Sehr K, Klimek J. Surface texture of four nanofilled and one hybrid composite after finishing. Oper Dent 2007;32:45-52.  Back to cited text no. 5
    
6.
Puckett AD, Fitchie JG, Kirk PC, Gamblin J. Direct composite restorative materials. Dent Clin North Am 2007;51:659-75, vii.  Back to cited text no. 6
    
7.
Stoddard JW, Johnson GH. An evaluation of polishing agents for composite resins. J Prosthet Dent 1991;65:491-5.  Back to cited text no. 7
    
8.
Joniot S, Salomon JP, Dejou J, Grégoire G. Use of two surface analyzers to evaluate the surface roughness of four esthetic restorative materials after polishing. Oper Dent 2006;31:39-46.  Back to cited text no. 8
    
9.
Kawai K, Urano M. Adherence of plaque components to different restorative materials. Oper Dent 2001;26:396-400.  Back to cited text no. 9
    
10.
Gordan VV, Patel SB, Barrett AA, Shen C. Effect of surface finishing and storage media on bi-axial flexure strength and microhardness of resin-based composite. Oper Dent 2003;28:560-7.  Back to cited text no. 10
    
11.
Jones CS, Billington RW, Pearson GJ. The in vivo perception of roughness of restorations. Br Dent J 2004;196:42-5.  Back to cited text no. 11
    
12.
Paravina RD, Roeder L, Lu H, Vogel K, Powers JM. Effect of finishing and polishing procedures on surface roughness, gloss and color of resin-based composites. Am J Dent 2004;17:262-6.  Back to cited text no. 12
    
13.
Patel SB, Gordan VV, Barrett AA, Shen C. The effect of surface finishing and storage solutions on the color stability of resin-based composites. J Am Dent Assoc 2004;135:587-94.  Back to cited text no. 13
    
14.
Marigo L, Rizzi M, La Torre G, Rumi G. 3-D surface profile analysis: Different finishing methods for resin composites. Oper Dent 2001;26:562-8.  Back to cited text no. 14
    
15.
Tjan AH, Chan CA. The polishability of posterior composites. J Prosthet Dent 1989;61:138-46.  Back to cited text no. 15
    
16.
Berger SB, Palialol AR, Cavalli V, Giannini M. Surface roughness and staining susceptibility of composite resins after finishing and polishing. J Esthet Restor Dent 2011;23:34-43.  Back to cited text no. 16
    
17.
Berastegui E, Canalda C, Brau E, Miquel C. Surface roughness of finished composite resins. J Prosthet Dent 1992;68:742-9.  Back to cited text no. 17
    
18.
Lu H, Roeder LB, Powers JM. Effect of polishing systems on the surface roughness of microhybrid composites. J Esthet Restor Dent 2003;15:297-303.  Back to cited text no. 18
    
19.
Toledano M, De la Torre FJ, Osorio R. Evaluation of two polishing methods for resin composites Am J Dent 1994;7:328-30.  Back to cited text no. 19
    
20.
Watanabe T, Miyazaki M, Takamizawa T, Kurokawa H, Rikuta A, Ando S. Influence of polishing duration on surface roughness of resin composites. J Oral Sci 2005;47:21-5.  Back to cited text no. 20
    

Top
Correspondence Address:
Dr. Shan Sainudeen
Sr Lecturer, Department of Cons and Endo, PMS Dental College, Golden Hills, Vattapara, Venkode, Thiruvananthapuram 695028, Kerala
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0972-0707.173208

Rights and Permissions


    Figures

  [Figure 1], [Figure 2], [Figure 3]
 
 
    Tables

  [Table 1], [Table 2], [Table 3], [Table 4], [Table 5]



 

Top
 
 
 
  Search
 
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Email Alert *
    Add to My List *
* Registration required (free)  
 


    Abstract
   Introduction
    Materials and Me...
   Results
   Discussion
   Conclusion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed1719    
    Printed69    
    Emailed0    
    PDF Downloaded189    
    Comments [Add]    

Recommend this journal