Journal of Conservative Dentistry
Home About us Editorial Board Instructions Submission Subscribe Advertise Contact e-Alerts Login 
Users Online: 378
Print this page  Email this page Bookmark this page Small font sizeDefault font sizeIncrease font size
ORIGINAL ARTICLE
Year : 2014  |  Volume : 17  |  Issue : 1  |  Page : 27-30

Comparative evaluation of the bonding efficacy of sixth and seventh generation bonding agents: An In-Vitro study


1 Department of Conservative Dentistry and Endodontics, Pushpagiri College of Dental Sciences, Tiruvalla, Kerala, India
2 Department of Conservative Dentistry and Endodontics, VMS Dental College, Salem, Tamil Nadu, India

Correspondence Address:
Manuja Nair
Department of Conservative Dentistry and Endodontics, Pushpagiri College of Dental Sciences, Pushpagiri Medicity, Perumthuruthy P.O, Tiruvalla - 689 107, Kerala
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0972-0707.124119

Rights and Permissions

Aims: To compare the shear bond strength of sixth generation and seventh generation bonding agents to dentin. Materials and Methods: Eighty human maxillary premolars were reduced to expose flat surface of dentin and divided into four equal groups, which were bonded using following bonding agents: Sixth generation bonding agents, Adper SE Plus and Xeno III and Seventh generation bonding agents, Adper Easy One and Xeno V. Composite cylinders were then built using a plastic mould on these prepared dentinal surfaces. Samples were stored in distilled water for 24 hours and tested for shear bond strength with universal testing machine. Shear force was applied perpendicular to the long axis of composite cylinder at adhesive-tooth interface until debonding occurred. The data so obtained were tabulated and analyzed statistically using independent-samples t test and analysis of variance (ANOVA) test Results: The seventh generation adhesives showed significantly higher shear bond strength to dentin compared to sixth generation adhesives (P < 0.01). The highest value of shear bond strength was obtained from Adper Easy One system, while Adper SE Plus gave the lowest shear bond strength values. Conclusions: Seventh generation adhesives are more advantageous than sixth generation adhesives in dentin bonding as it requires less time, fewer steps, and better bond strength.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed3582    
    Printed98    
    Emailed0    
    PDF Downloaded538    
    Comments [Add]    

Recommend this journal